Page 177 - 2018_IRC
P. 177
FLOORS
SHEATHING
WEB STIFFENER
RIM TRACK
MIN. 33 MIL THICK
4-NO. 8 SCREWS
MIN. 4-10d OR 6-8d
COMMON NAILS
3 IN. × 3 IN. × 33 MIL
STEEL PLATE (MIN.)
ANCHOR BOLT OR OTHER
CONNECTION AS REQUIRED
WOOD SILL AS REQUIRED
FOUNDATION
SILL SEALER AS REQUIRED
For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm.
FIGURE R505.3.1(2)
FLOOR-TO-WOOD-SILL CONNECTION
WEB STIFFENER
RIM TRACK
(MIN. 33 MIL THICK)
SHEATHING
SILL SEALER
AS REQUIRED
JOIST
ANCHOR BOLT OR OTHER
CONNECTION AS REQUIRED
6 IN. × 6 IN. × 54 MIL CLIP ANGLE FASTENED
TO TRACK WITH 8-NO. 8 SCREWS
FOUNDATION
For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm.
FIGURE R505.3.1(3)
FLOOR-TO-FOUNDATION CONNECTION
152 2018 INTERNATIONAL RESIDENTIAL CODE ®
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.