Page 176 - 2018_IRC
P. 176

FLOORS



                                                         TABLE R505.3.1(2)
                                                                            a
                                                    FLOOR FASTENING SCHEDULE
                  DESCRIPTION OF BUILDING ELEMENTS   NUMBER AND SIZE OF FASTENERS        SPACING OF FASTENERS
             Floor joist to track of an interior load-bearing wall
             in accordance with Figures R505.3.1(7) and    2 No. 8 screws       Each joist
             R505.3.1(8)
             Floor joist to track at end of joist          2 No. 8 screws       One per flange or two per bearing stiffener
                                                                                6 in. o.c. on edges and 12 in. o.c. at intermediate
             Subfloor to floor joists                       No. 8 screws
                                                                                supports
             For SI: 1 inch = 25.4 mm.
             a. All screw sizes shown are minimum.








                  RIM TRACK
                  (MIN. 33 MIL THICK)



                 WEB STIFFENER

                 NO. 8 SCREWS THROUGH
                 JOIST FLANGE, CLIP ANGLE
                 OR BENT STIFFENER
                                                                                                     SHEATHING








                  TRACK

                                                                                                     JOIST


                  FASTEN RIM TRACK TO
                  WALL TRACK WITH NO. 8
                  SCREWS AT 24 IN. O.C.
                                                                              NO. 8 SCREW THROUGH
                                                                              EACH FLANGE



                                                                             LOAD-BEARING STUD


              For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm.
                                                         FIGURE R505.3.1(1)
                                       FLOOR-TO-EXTERIOR LOAD-BEARING WALL STUD CONNECTION















             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                               151
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.