Page 236 - 2018_IRC
P. 236

WALL CONSTRUCTION


                                                         TABLE R602.10.6.5
                                            METHOD BV-WSP WALL BRACING REQUIREMENTS
                                                       BRACED WALL LINE LENGTH (FEET)
                                                                                             SINGLE-STORY  CUMULATIVE
               SEISMIC DESIGN   STORY         10        20        30        40         50     HOLD-DOWN   HOLD-DOWN
                CATEGORY                                                                        FORCE      FORCE
                                                  Minimum Total Length (feet) of Braced Wall Panels   (pounds) a  (pounds) b
                                                      Required Along each Braced Wall Line
                                              4.0       7.0       10.5      14.0      17.5       NA          —




                                              4.0       7.0       10.5      14.0      17.5      1900         —
                   D
                     0
                                              4.5       9.0       13.5      18.0      22.5      3500        5400




                                              6.0       12.0      18.0      24.0      30.0      3500        8900



                                              4.5       9.0       13.5      18.0      22.5      2100         —



                   D 1                        4.5       9.0       13.5      18.0      22.5      3700        5800




                                              6.0       12.0      18.0      24.0      30.0      3700        9500




                                              5.5       11.0      16.5      22.0      27.5      2300         —




                   D 2                        5.5       11.0      16.5      22.0      27.5      3900        6200




                                              NP        NP        NP        NP        NP         NA          NA



             For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.479 kPa, 1 pound-force = 4.448 N.
             NP = Not Permitted.
             NA = Not Applicable.
             a. Hold-down force is minimum allowable stress design load for connector providing uplift tie from wall framing at end of braced wall panel at the noted story
               to wall framing at end of braced wall panel at the story below, or to foundation or foundation wall. Use single-story hold-down force where edges of braced
               wall panels do not align; a continuous load path to the foundation shall be maintained.
             b. Where hold-down connectors from stories above align with stories below, use cumulative hold-down force to size middle- and bottom-story hold-down
               connectors.