Page 238 - 2018_IRC
P. 238

WALL CONSTRUCTION



                    the panel, full-depth blocking at 16-inch (406 mm)  splices shall be face-nailed with not less than eight 16d
                    spacing shall be provided between the parallel fram-  nails on each side of the splice.
                    ing members to each side of the braced wall panel in  R602.10.8.2 Connections to roof framing. Top plates
                    accordance with Figure R602.10.8(2). Fastening of  of exterior braced wall panels shall be attached to raf-
                    blocking and wall plates shall be in accordance with  ters  or  roof  trusses  above  in  accordance  with  Table
                    Table R602.3(1) and Figure R602.10.8(2).           R602.3(1) and this section. Where required by this sec-
                  3. Connections  of  braced wall panels  to  concrete  or  tion, blocking between rafters or roof trusses shall be
                    masonry  shall  be  in  accordance  with  Section  attached to top plates of braced wall panels and to raf-
                    R403.1.6.                                          ters  and  roof  trusses  in  accordance  with  Table
                  R602.10.8.1 Braced wall panel connections for Seis-  R602.3(1). A continuous band, rim or header joist or
                  mic Design Categories D , D  and D .   Braced wall   roof  truss  parallel  to  the  braced wall panels  shall  be
                                                  2
                                        0
                                           1
                  panels  shall  be  fastened  to  required  foundations  in  permitted to replace the blocking required by this sec-
                  accordance with Section R602.11.1, and top plate lap  tion. Blocking shall not be required over openings in
                                                                       continuously sheathed braced wall lines. In addition to
                                                                                   CONTINUOUSLY SHEATHED
                                   CONTINUOUSLY SHEATHED                             BRACED WALL LINE
                                     BRACED WALL LINE







                        RETURN                                          HOLD-
                        PANEL                                           DOWN
                                     BRACED WALL PANEL AT               DEVICE      BRACED WALL PANEL AT
                                     END OF BRACED WALL LINE                        END OF BRACED WALL LINE
                                   END CONDITION 1                                 END CONDITION 2
                                CONTINUOUSLY SHEATHED
                                   BRACED WALL LINE                              CONTINUOUSLY SHEATHED
                                                                                    BRACED WALL LINE







                                                                       RETURN
                                                                       PANEL    D*
                                  48″ MINIMUM BRACED WALL PANEL                     10′ MAX     FIRST BRACED
                                  AT END OF BRACED WALL LINE                                    WALL PANEL
                                                                      * SEE REQUIREMENTS
                                   END CONDITION 3                                 END CONDITION 4
                                 CONTINUOUSLY SHEATHED
                                   BRACED WALL LINE                               REQUIREMENTS
                                                                   Return panel: 24″ for braced wall lines sheathed with
                                                                              wood structural panels
                                                                              32″ for braced wall lines sheathed with
                                                                              structural fiberboard
                                                                   Distance D:  24″ for braced wall lines sheathed with
                                                                              wood structural panels
                                                                              32″ for braced wall lines sheathed with
                                                                              structural fiberboard
                                                                   Hold-down  800 lbs capacity fastened to the edge of the
                            HOLD-DOWN         FIRST BRACED
                            DEVICE            WALL PANEL           device:    braced wall panel closest to the corner and
                                                                              to the foundation or floor framing below
                                   END CONDITION 5
             For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound = 4.45 N.


                                                         FIGURE R602.10.7
                                  END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING


             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                               213
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   233   234   235   236   237   238   239   240   241   242   243