Page 242 - 2018_IRC
P. 242

WALL CONSTRUCTION



                                                                         48″ OR LESS

                                                                                          BRACED WALL PANEL
                                                                                       ½″ ANCHOR BOLTS PER
                                                                                       BRACED WALL PANEL
                                48″ OR LESS                                            REQUIREMENTS
                                              BRACED WALL PANEL
                                             ½″ ANCHOR BOLTS PER BRACED                 #4 BAR
                                             WALL PANEL REQUIREMENTS
                                                                                          BOND BEAM
                                               BOND BEAM WITH 1-#4 BAR

                                              #4 BAR MIN.; FIELD BEND 6″  48″ MAXIMUM  20″ LAP, TYP.
                          24″ MAX.                                                           #4 BAR
                                              EXTENSION INTO BOND BEAM
                                                            6″ MIN.                                  6″ MIN.


                                            20″ MIN. TYP.                            20″ MIN. TYP.
                              3″ COVER                                 3″ COVER
                                 SHORT STEM WALL REINFORCEMENT              TALL STEM WALL REINFORCEMENT
                               48″ OR LESS                           BRACED WALL
                                                                     PANEL
                                                BRACED WALL PANEL
                                                                                               BOND BEAM
                                               BOND BEAM WITH 1-#4 BAR
                          48″ MAXIMUM         5 BE PERMITTED TO BE   FACE BRICK               8″ MIN. CMU
                                                                     OPTIONAL
                                               /8″ THREADED RODS SHALL
                                              SUBSTITUTED FOR ANCHOR
                                              BOLTS AND REBAR

                                                           8″ MIN.


                                  3″ COVER  MIN. 2″ CUT WASHERS
                               OPTIONAL STEM WALL REINFORCEMENT           TYPICAL STEM WALL SECTION
                                            NOTE: GROUT BOND BEAMS AND ALL CELLS THAT CONTAIN
                                            REBAR, THREADED RODS AND ANCHOR BOLTS.

             For SI: 1 inch = 25.4 mm.
                                                         FIGURE R602.10.9
                                        MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
                  R602.10.10.1  Cripple  wall  bracing  for  Seismic   the  required  bracing  length  adjusted  by  0.7.  If  the
                  Design Categories D  and D  and townhouses in Seis-  required  length  can  still  not  be  provided,  the  cripple
                                         1
                                   0
                  mic Design Category C. In addition to the requirements  wall  shall  be  designed  in  accordance  with  accepted
                  in Section R602.10.10, the distance between adjacent  engineering practice.
                  edges of braced wall panels for cripple walls along a  R602.10.10.2  Cripple  wall  bracing  for  Seismic
                  braced wall line shall be 14 feet (4267 mm) maximum.   Design Category D . In Seismic Design Category D ,
                                                                                                                  2
                                                                                       2
                    Where  braced wall lines  at  interior  walls  are  not  cripple walls shall be braced in accordance with Tables
                  supported on a continuous foundation below, the adja-  R602.10.3(3) and R602.10.3(4).
                  cent  parallel  cripple  walls,  where  provided,  shall  be  R602.10.10.3 Redesignation of cripple walls. Where
                  braced  with  Method  WSP  or  Method  CS-WSP  in    all cripple wall segments along a braced wall line do
                  accordance with Section R602.10.4. The length of brac-  not exceed 48 inches (1219 mm) in height, the cripple
                  ing required in accordance with Table R602.10.3(3) for  walls shall be permitted to be redesignated as a first-
                  the cripple walls shall be multiplied by 1.5. Where the  story  wall  for  purposes  of  determining  wall  bracing
                  cripple walls do not have sufficient length to provide  requirements.  Where  any  cripple  wall  segment  in  a
                  the required bracing, the spacing of panel edge fasten-  braced wall  line  exceeds  48  inches  (1219  mm)  in
                  ers shall be reduced to 4 inches (102 mm) on center and  height,  the  entire  cripple  wall  shall  be  counted  as  an