WALL CONSTRUCTION


                                                                                    1
                  R606.6.3.1 Joist bearing. Joists shall have a bearing of  instructions,  / -inch (13 mm) bolts spaced not more
                                                                                     2
                             1
                  not less than 1 /  inches (38 mm), except as provided in  than 6 feet (1829 mm) on center, or other approved
                              2
                  Section R606.6.3, and shall be supported in accordance  anchors. Anchors shall be embedded not less than 16
                  with Figure R606.11(1).                                inches (406 mm) into the masonry, or be hooked or
               R606.6.4 Lateral support. Masonry walls shall be later-   welded to bond beam reinforcement placed not less
               ally supported in either the horizontal or the vertical direc-  than 6 inches (152 mm) from the top of the wall.
               tion. The maximum spacing between lateral supports shall  R606.6.4.2.2  Floor  diaphragms.  Masonry  walls
               not exceed the distances in Table R606.6.4. Lateral sup-  shall  be  anchored  to  floor  diaphragm  framing  by
               port shall be provided by cross walls, pilasters, buttresses  metal strap anchors spaced in accordance with the
               or structural frame members where the limiting distance is  manufacturer’s  instructions,  / -inch-diameter  (13
                                                                                                  1
                                                                                                   2
               taken horizontally, or by floors or roofs where the limiting  mm) bolts spaced at intervals not to exceed 6 feet
               distance is taken vertically.                             (1829  mm)  and  installed  as  shown  in  Figure
                               TABLE R606.6.4                            R606.11(1), or by other approved methods.
               SPACING OF LATERAL SUPPORT FOR MASONRY WALLS       R606.7 Piers. The unsupported height of masonry piers shall
                                 MAXIMUM WALL LENGTH TO THICKNESS
                 CONSTRUCTION                                     not exceed 10 times their least dimension. Where structural
                                   OR WALL HEIGHT TO THICKNESS a, b
              Bearing walls:                                      clay tile or hollow concrete masonry units are used for isolated
                 Solid or solid grouted       20                  piers to support beams and girders, the cellular spaces shall be
                 All other                    18                  filled solidly with grout or Type M or S mortar, except that
              Nonbearing walls:                                   unfilled  hollow  piers  shall  be  permitted  to  be  used  if  their
                 Exterior                     18                  unsupported  height  is  not  more  than  four  times  their  least
                 Interior                     36                  dimension. Where hollow masonry units are solidly filled with
             For SI: 1 foot = 304.8 mm.                           grout or Type M, S or N mortar, the allowable compressive
             a. Except for cavity walls and cantilevered walls, the thickness of a wall shall  stress shall be permitted to be increased as provided in Table
               be its nominal thickness measured perpendicular to the face of the wall. For  R606.9.
               cavity walls, the thickness shall be determined as the sum of the nominal
               thicknesses  of  the  individual  wythes.  For  cantilever  walls,  except  for  R606.7.1 Pier cap. Hollow piers shall be capped with 4
               parapets, the ratio of height to nominal thickness shall not exceed 6 for solid  inches (102 mm) of solid masonry or concrete, a masonry
               masonry, or 4 for hollow masonry. For parapets, see Section R606.4.4.   cap block, or shall have cavities of the top course filled
             b. An additional unsupported height of 6 feet is permitted for gable end walls.   with concrete or grout.
                  R606.6.4.1  Horizontal  lateral  support.  Lateral  sup-
                  port in the horizontal direction provided by intersecting  R606.8 Chases. Chases and recesses in masonry walls shall
                  masonry walls shall be provided by one of the methods  not be deeper than one-third the wall thickness. The maximum
                  in Section R606.6.4.1.1 or R606.6.4.1.2.        length of a horizontal chase or horizontal projection shall not
                                                                  exceed 4 feet (1219 mm) and shall have not less than 8 inches
                    R606.6.4.1.1 Bonding pattern. Fifty percent of the  (203 mm) of masonry in back of the chases and recesses and
                    units at the intersection shall be laid in an overlap-  between adjacent chases or recesses and the jambs of openings.
                    ping masonry bonding pattern, with alternate units  Chases and recesses in masonry walls shall be designed and
                    having a bearing of not less than 3 inches (76 mm)  constructed so as not to reduce the required strength or required
                    on the unit below.                            fire resistance of the wall and shall not be permitted within the
                    R606.6.4.1.2  Metal  reinforcement.  Interior  non-  required  area  of  a  pier.  Masonry  directly  above  chases  or
                    load-bearing walls shall be anchored at their intersec-  recesses wider than 12 inches (305 mm) shall be supported on
                    tions, at vertical intervals of not more than 16 inches  noncombustible lintels.
                    (406 mm) with joint reinforcement of not less than 9  R606.9 Allowable stresses. Allowable compressive stresses
                                            1
                    gage [0.148 inch (4 mm)], or  / -inch (6 mm) galva-  in masonry shall not exceed the values prescribed in Table
                                             4
                    nized  mesh  hardware  cloth.  Intersecting  masonry  R606.9. In determining the stresses in masonry, the effects of
                    walls, other than interior nonload-bearing walls, shall  all loads and conditions of loading and the influence of all
                    be anchored at vertical intervals of not more than 8  forces affecting the design and strength of the several parts
                    inches (203 mm) with joint reinforcement of not less  shall be taken into account.
                    than 9 gage (4 mm) and shall extend not less than 30
                    inches (762 mm) in each direction at the intersection.  R606.9.1  Combined  units.  In  walls  or  other  structural
                    Other metal ties, joint reinforcement or anchors, if  members composed of different kinds or grades of units,
                    used, shall be spaced to provide equivalent area of  materials or mortars, the maximum stress shall not exceed
                    anchorage to that required by this section.      the allowable stress for the weakest of the combination of
                                                                     units, materials and mortars of which the member is com-
                  R606.6.4.2  Vertical  lateral  support.  Vertical  lateral  posed. The net thickness of any facing unit that is used to
                  support of masonry walls in Seismic Design Category  resist stress shall be not less than 1 /  inches (38 mm).
                                                                                                1
                  A, B or C shall be provided in accordance with one of                           2
                  the methods in Section R606.6.4.2.1 or R606.6.4.2.2.  R606.10 Lintels. Masonry over openings shall be supported
                                                                  by  steel  lintels,  reinforced  concrete  or  masonry  lintels  or
                    R606.6.4.2.1 Roof structures. Masonry walls shall  masonry arches, designed to support load imposed.
                    be  anchored  to  roof  structures  with  metal  strap
                    anchors spaced in accordance with the manufacturer’s