Page 295 - 2018_IRC
P. 295

WALL CONSTRUCTION





                                     ROOF CONNECTORS AT
                                     48 IN. MAX. O.C.               ROOF


                               #4 BARS AROUND                                         #4 BARS (MIN.) AT
                               OPENINGS                                               DIAPHRAGMS
                                                                                      CONT. THRU C.J.
                                      DETAIL B
                   #4 BARS WITHIN 8 IN. OF ENDS                                       #4 BARS (MIN.)
                   OF WALLS AND AT CORNERS                                            WITHIN 8 IN. OF
                                                                                      ALL C.J.’S

                                                                                      CONTROL JOINT
                                                                                      (C.J.)

                                     #4 BARS AT 10 FT O.C.       24 IN. OR      #4 BARS AT 10 FT O.C. OR W1.7
                                                                 40 db          JOINT REINFORCED AT 16 IN. O.C.
                                             MINIMUM REINFORCEMENT FOR MASONRY WALLS


                                                                    ANCHOR BOLTS
                                                                                                    5 IN. MAX

                 2 IN. PLATE WITH ½ IN. Φ BOLTS        TWO #4 LATERAL TIES WITHIN
                 NOT MORE THAN 4 FT O.C.               TOP 5 IN. OF COLUMN THAT
                 EMBEDDED 4 IN. MIN.                   ENCLOSE ANCHOR BOLTS AND                   COLUMN TIES
                                                       VERTICAL REINFORCEMENT


                                        3 IN. x 3 IN. x ¼ IN. CLIP  VERTICAL COLUMN
                  BOND BEAM STEEL       ANGLE 4 FT O.C.          REINFORCEMENT
                  TWO ½ IN. BARS        ONE ½ IN. BOLT
           LINTEL STEEL
           SEE SECTION R606.10                              REINFORCEMENT SHALL
                                                            HAVE MIN. ¼ IN.
                                                            CLEARANCE
                  REINFORCEMENT—                   12 IN. MAX.
                  SEE SECTIONS                     BEFORE
                  R606.12.2.2.3 AND                GROUTING
                  R606.12.2.3.3
                       NOT HEADER
                       COURSE
                                                METAL TIES                           WHERE INTERIOR
                                         DOWEL  SEE SECTION                          STUD PARTITION
                                                                                     MEETS WALL BOLT
                                                R608.1.2
                                                                                     END STUD WITH
                          LAP 40 DIA.                                                ½ IN. Φ BOLTS
                                                                                     3 FT O.C.
                                               HEADER COURSES
                                               NOT PERMITTED

                                                   MIN. ¾ IN. GROUT                        LAP 40 DIA.
                                                                                        SECTION 1



         For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.

                                                     FIGURE R606.11(2)
                  REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C


         270                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®