Page 296 - 2018_IRC
P. 296

WALL CONSTRUCTION




                                    ROOF CONNECTORS AT
                                    48 IN. MAX. O.C.               ROOF



                               #4 BARS AROUND                                         #4 BARS (MIN.) AT
                               OPENINGS                                               DIAPHRAGMS
                                                                                      CONT. THRU C.J.
                                      DETAIL B

                  #4 BARS WITHIN 8 IN. OF ENDS                                        #4 BARS (MIN.)
                  OF WALLS AND AT CORNERS                                             WITHIN 8 IN. OF
                                                                                      ALL C.J.’S
                                                                                      CONTROL JOINT
                                                                                      (C.J.)


                                     #4 BARS AT 48 IN. O.C.      24 IN. OR      #4 BARS at 48 IN. O.C.
                                                                 40 db
                                            MINIMUM REINFORCEMENT FOR MASONRY WALLS
                3 IN. x 3¼ IN. CLIP ANGLE 4 FT. O.C.,
                ONE ½ Φ IN. BOLT                                        ANCHOR BOLTS
                                                                                                        5 IN. MAX

                                                            TWO #4 LATERAL TIES WITHIN
                                    BOND BEAM TWO           TOP 5 IN. OF COLUMN THAT
                                    ½ Φ IN. BARS STEEL      ENCLOSE ANCHOR BOLTS AND                   #3 COLUMN
                                                            VERTICAL REINFORCEMENT                     TIES AT 8 IN.
                                                                                                       MAX.
                                    ½ IN. BOLTS NOT MORE              VERTICAL COLUMN
                                    THAN 4 FT. O.C. IN CELLS          REINFORCEMENT
                                    WITH VERTICAL ROD
                      HEIGHT        WHERE POSSIBLE
                      8 FT. MAX.    EMBEDDED 4 IN. MIN.
                                     TIE COURSE                      LINTEL BAR OR
                                                                     BARS—SEE
                                     REINFORCEMENTS—                 SECTION R606.10
                                     SEE SECTIONS
                                     R606.12.2.2.3, R606.12.3.2
                                     AND R606.12.4
                                     DOWEL 2 FT. 6 IN.      SECTION C  3/8 IN. Φ DOWEL   3/8 IN. Φ ROD
                                     LONG
                                                                                                 FOUNDATION
                     6 IN.                          6 IN. MIN.
                                     18 IN. MIN.
                                                   6 IN.                                    INSPECTION OPENING
                         6 IN.                                                              NOT REQUIRED IF
                                     14 IN.                 14 IN.               DETAIL “A”  INSPECTED AT THE
                                                                                            COURSE
                          FOUNDATION FOR              FOUNDATION FOR
                           WOOD FLOOR                 CONCRETE FLOOR




             For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
             Note: A full bed joint must be provided. Cells containing vertical bars are to be filled to the top of wall and provide inspection opening as shown on detail “A.”
             Horizontal bars are to be laid as shown on detail “B.” Lintel bars are to be laid as shown on Section C.



                                                         FIGURE R606.11(3)
                      REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D , D  OR D 2
                                                                                                   0
                                                                                                     1