Page 321 - 2018_IRC
P. 321

WALL CONSTRUCTION



                                                 TABLE R608.7(1C)—continued
                                   UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH
                                    EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE a, c, d, e, f, g
                                   UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN SIDEWALLS FOR WIND PARALLEL TO RIDGE (feet)
                                                            Basic Wind Speed Exposure (mph)
          SIDEWALL ENDWALL  ROOF    115B      120B      130B      140B      150B       160B
           LENGTH  LENGTH  SLOPE
            (feet)  (feet)            —         —       110C      119C      127C       136C        Minimum b
                                      —         —          —      110D      117D       125D
                                                       First story of two story
                           < 1:12   3.03      3.30      3.88      4.49      5.16       5.87          2.52
                           5:12     3.24      3.52      4.14      4.80      5.51       6.26          2.70
                     15
                           7:12     3.33      3.62      4.25      4.93      5.66       6.44          2.79
                           12:12    3.58      3.90      4.58      5.31      6.10       6.94          3.01
                           < 1:12   5.50      5.99      7.03      8.16      9.36      10.65          5.14
                           5:12     6.21      6.76      7.93      9.20      10.56     12.01          5.86
                     30
                           7:12     6.52      7.10      8.34      9.67      11.10     12.63          6.19
                           12:12    7.41      8.06      9.46      10.97     12.60     14.33          7.10
            < 30
                           < 1:12   8.00      8.71      10.22     11.85     13.61     15.48          7.85
                           5:12     9.52     10.37      12.17     14.11     16.20     18.43          9.48
                     45
                           7:12    10.21     11.12      13.05     15.14     17.38     19.77         10.21
                           12:12   12.13     13.20      15.50     17.97     20.63     23.47         12.25
                           < 1:12  10.56     11.50      13.50     15.65     17.97     20.44         10.65
                           5:12    13.24     14.41      16.91     19.62     22.52     25.62         13.54
                     60
                           7:12    14.45     15.73      18.46     21.41     24.58     27.97         14.85
                           12:12   17.80     19.38      22.75     26.38     30.29     34.46         18.48
                           < 1:12   8.39      9.14      10.72     12.44     14.28     16.25          7.85
                           5:12     9.97     10.86      12.74     14.78     16.97     19.30          9.48
                     45
                           7:12    10.69     11.64      13.66     15.84     18.19     20.69         10.21
                           12:12   12.67     13.80      16.19     18.78     21.56     24.53         12.25
             60
                           < 1:12  11.37     12.38      14.53     16.85     19.35     22.01         10.65
                           5:12    14.18     15.44      18.12     21.02     24.13     27.45         13.54
                     60
                           7:12    15.46     16.83      19.75     22.91     26.29     29.92         14.85
                           12:12   18.98     20.66      24.25     28.13     32.29     36.74         18.48
         For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s, 1 pound-force per linear foot = 0.146 kN/m, 1 pound per square foot = 47.88 Pa.
         a. Tabulated lengths were derived by calculating design wind pressures in accordance with Figure 28.4-1 of ASCE 7 for a building with a mean roof height of 35
           feet, topographic factor, K , equal to 1.0, and Risk Category II. The design pressures were used to calculate forces to be resisted by solid wall segments in each
                           zt
           sidewall. The forces to be resisted by each wall line were then divided by the default design strength of 840 pounds per linear foot of length to determine the
           unreduced length, UR, of solid wall length required in each sidewall. The actual mean roof height of the building shall not exceed the least horizontal
           dimension of the building.
         b. Tabulated lengths in the “minimum” column are based on the requirement of Section 28.4.4 of ASCE 7 that the main windforce-resisting system be designed
           for a minimum pressure of 16 psf multiplied by the wall area of the building and 8 psf multiplied by the roof area of the building projected onto a vertical
           plane  normal to  the  assumed  wind direction. Tabulated lengths  in  shaded  cells are less  than  the  “minimum”  value. Where  the  minimum controls, it  is
           permitted to be reduced in accordance with Notes c, d and e. See Section R608.7.1.1.
         c. For buildings with a mean roof height of less than 35 feet, tabulated lengths are permitted to be reduced by multiplying by the appropriate factor, R 1 , from
           Table R608.7(2). The reduced length shall be not less than the “minimum” value shown in the table.
         d. Tabulated lengths for “one story or top story of two story” are based on a floor-to-ceiling height of 10 feet. Tabulated lengths for “first story of two story” are
           based on floor-to-ceiling heights of 10 feet each for the first and second story. For floor-to-ceiling heights less than assumed, use the lengths in this table or
           Table R608.7(1A) or (1B), or multiply the value in the table by the reduction factor, R , from Table R608.7(3).
                                                                  2
         e. Tabulated lengths are based on the default design shear strength of 840 pounds per linear foot of solid wall segment. The tabulated lengths are permitted to be
           reduced by multiplying by the applicable reduction factor for design strength, R , from Table R608.7(4).
                                                              3
         f. The reduction factors, R 1 , R 2  and R 3 , in Tables R608.7(2), R608.7(3), and R608.7(4), respectively, are permitted to be compounded, subject to the limitations
           of  Note  b.  However,  the  minimum  number  and  minimum  length  of  solid  walls  segments  in  each  wall  line  shall  comply  with  Sections  R608.7.1  and
           R608.7.2.1, respectively.
         g. For intermediate values of sidewall length, endwall length, roof slope and basic wind speed, use the next higher value, or determine by interpolation.




         296                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.