WALL CONSTRUCTION





             DETAIL    NOM. WALL     REINFORCEMENT LAYOUT AT ENDS OF
               NO.   THICKNESS, IN.         SOLID WALL SEGMENTS                         NOTES

                                                                            For SI: 1 inch = 25.4 mm.
                                                   3 inch Max. Typical
                                                   2 inch Typical            1. See Table R608.7(4) for use
                                                                                of details.
                1          4
                                                                             2. Minimum length of solid wall
                                                                                segment and size and grade
                2          4                                                    of reinforcement in each end
                                                                                of each solid wall segment
                                                                                shall be determined from
                                                                                Table R608.7(4).
                           6
                3          8
                           10                                                3.. For minimum cover requirements,
                                                                                see Section R608.5.4.1.


                                                                             4.. For details 3 - 8 where two
                4          6
                                                                                or more bars are in the same
                                                                                row parallel to the end of the
                                                                                segment, place bars so that
                                       1 inch Min. clear spacing Typical        corner bars are as close to the
                                                                                sides of the wall segments as
                                                                                minimum cover requirements
                                                                                of Section R608.5.4.1 will permit.
                5          8



                                                                             5.. For waffle- and screen-grid walls,
                                                                                each end of each solid wall
                                                                                segment shall have rectangular
                6          8                                                    flanges. In the through-the-wall
                                                                                dimension, the flange shall be not
                                                                                less than 5½ inches for 6-inch
                                                                                nominal waffle- and screen-grid
                                                                                forms, and not less than 7½
                                                                                inches for 8-inch nominal waffle-
                                                                                grid forms. In the in-plane
                                                                                dimension, flanges shall be long
                7          10                                                   enough to accommodate the
                                                                                vertical reinforcement required
                                                                                by the layout detail selected and
                                                                                provide the cover required by
                                     *                                          Section R608.5.4.1. If necessary
                                                                                to achieve the required
                                                                                dimensions, form material shall be
                                                                                removed or flat wall forms are
                8          10                                                   permitted. See Table R608.7(4),
                                                                                Note e.


                                       * For minimum cover see Section R608.5.4.1





                                                      FIGURE R608.7(2)
                                           VERTICAL REINFORCEMENT LAYOUT DETAIL