WALL CONSTRUCTION



                 Horizontal  reinforcement  placed  above  and  below  located as required by  the applicable  detail in  Figure
              an opening shall extend beyond the edges of the open-  R608.7(2). Where the vertical reinforcement required by
              ing the dimension required to develop the bar in tension  this section is used to satisfy the requirements of Section
              in accordance with Section R608.5.4.4.               R608.7.2.2.2 in waffle- and screen-grid walls, a concrete
                Exception:  Continuous  horizontal  wall  reinforce-  flange shall be created at the ends of the solid wall seg-
                ment placed within 12 inches (305 mm) of the top of  ments in accordance with Table R608.7(4), Note e. In
                the wall story as required in Sections R404.1.3.2 and  the top-most story, the reinforcement shall terminate in
                R608.6.2 is permitted in lieu of top or bottom lintel  accordance with Section R608.6.4.
                reinforcement required by Section R608.8.2 provided  R608.8.2 Lintels. Lintels shall be provided over all open-
                that  the  continuous  horizontal  wall  reinforcement  ings equal to or greater than 2 feet (610 mm) in width. Lin-
                meets the location requirements specified in Figures  tels  with  uniform  loading  shall  conform  to  Sections
                R608.8(2),  R608.8(3),  and  R608.8(4)  and  the  size  R608.8.2.1 and R608.8.2.2, or Section R608.8.2.3. Lintels
                requirements specified in Tables R608.8(2) through  supporting concentrated loads, such as from roof or floor
                R608.8(10).                                      beams or girders, shall be designed in accordance with ACI
              R608.8.1.2 Vertical reinforcement. Not less than one  318.
              No. 4 bar [Grade 40 (280 MPa)] shall be provided on  R608.8.2.1 Lintels designed for gravity load-bearing
              each side of openings equal to or greater than 2 feet (610  conditions. Where a lintel will be subjected to gravity
              mm) in width. The vertical reinforcement required by  load conditions 1 through 5 of Table R608.8(1), the clear
              this section shall extend the full height of the wall story  span  of  the  lintel  shall  not  exceed  that  permitted  by
              and shall be located within 12 inches (305 mm) of each  Tables  R608.8(2)  through  R608.8(8).  The  maximum
              side of the opening. The vertical reinforcement required  clear span of lintels with and without stirrups in flat walls
              on each side of an opening by this section is permitted to  shall  be  determined  in  accordance  with  Tables
              serve as reinforcement at the ends of solid wall segments  R608.8(2) through R608.8(5), and constructed in accor-
              in accordance with Section R608.7.2.2.2, provided it is

                                                                 SEE FIGURES R608.8(2),
                     CONTINUOUS BAR AS REQUIRED                  R608.8(3) AND R608.8(4)
                     BY SECTION R608.6.2 SHALL BE
                     PERMITTED TO BE USED AS LINTEL
                     REINFORCMENT WHERE LOCATED                                          TOP AND BOTTOM
                     AS SHOWN IN FIGURES R608.8(2)                       CENTER DISTANCE,  LINTEL REINFORCEMENT
                     R608.8(3) AND R608.8(4)                             A, NOT REQUIRING  AS REQUIRED—SEE
                                             FLAT AND WAFFLE-GRID-       STIRRUPS        SECTION R608.8.2
                                             8 IN. MIN. SCREEN-GRID-
                                             12 IN. MIN.
               TOP OF
               WALL STORY
                                                                         A


                                                            *                         *
                                             <2F T
                                                                        ≥ 2FT






                                                             *                        *
                                                                         SEE
                                                                    SECTION R608.8.1
                                                                 OPENING REINFORCEMENT
                                                                     AS REQUIRED
                             WALL REINFORCEMENT
                             AS REQUIRED
                                                            VERTICAL REINFORCEMENT BESIDE OPENING.
                       * LENGTH REQUIRED TO                 SEE SECTION R608.8.1.2
                        DEVELOP BAR IN TENSION-
                        SEE SECTION R608.8.1.1
                                               ELEVATION OF WALL
         For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
                                                     FIGURE R608.8(1)
                                                REINFORCEMENT OF OPENINGS