WALL CONSTRUCTION


                                                     TABLE R608.9(12)
                          COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL a, b, c, d, e
                                                            BASIC WIND SPEED (mph) AND WIND EXPOSURE CATEGORY
            ANCHOR BOLT SPACING  TENSION TIE SPACING  115B      120B      130B       140B      150B      160B
                 (inches)             (inches)         —         —        110C       119C      127C      136C
                                                       —         —         —         110D      117D      125D
                   12                   12                                                                6
                   12                   24                                                                6
                   16                   16                                                      6         6
                   16                   32                                                      6         6
                  19.2                 19.2                                                     6         6
                  19.2                 38.4                                           6         6         6
                   24                   24                                            6         6        6B

         For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s.
         a. This table is for use with the detail in Figure R608.9(12). Use of this detail is permitted where a cell is not shaded.
         b. Wall design per other provisions of Section R608 is required.
         c. For wind design, minimum 4-inch-nominal wall is permitted in cells that do not contain a number.
         d. Number 6 indicates minimum permitted nominal wall thickness in inches necessary to develop required strength (capacity) of connection. As a minimum, this
           nominal thickness shall occur in the portion of the wall indicated by the cross hatching in Figure R608.9(12). For the remainder of the wall, see Note b.
                            5
         e. Letter “B” indicates that a  / -inch-diameter anchor bolt is required.
                             8





















































         346                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.