                                                      TABLE R610.5(1)
                       MINIMUM THICKNESS FOR SIP WALL SUPPORTING  SIP OR LIGHT-FRAME ROOF ONLY (inches)
                                                                                                 a
                                                     BUILDING WIDTH (ft)
          ULTIMATE DESIGN
            WIND SPEED                 24              28              32              36             40
              V ult  (mph)  SNOW
                          LOAD
                           (psf)  Wall Height (feet)  Wall Height (feet)  Wall Height (feet)  Wall Height (feet)  Wall Height (feet)
           Exp. B  Exp. C
                                  8    9    1  0  8    9          1  0  8  9  1  0  8  9    1  0  8    9    1  0
                           20    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5
                           30    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5
           110      —
                           50    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5
                           70    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   6.5  4.5  4.5  6.5
                           20    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5
                           30    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5
           115      —
                           50    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   4.5  4.5  4.5   4.5  4.5  4.5  6.5
                           70    4.5   4.5  4.5  4.5   4.5  4.5  4.5  4.5   6.5  4.5  4.5  DR    4.5  4.5  DR
                           20    4.5   4.5  6.5  4.5   4.5  6.5  4.5  4.5   6.5  4.5  4.5  DR    4.5  4.5  DR
                           30    4.5   4.5  6.5  4.5   4.5  6.5  4.5  4.5   DR   4.5  4.5  DR    4.5  4.5  DR
           130     110
                           50    4.5   4.5  DR   4.5   4.5  DR   4.5  4.5   DR   4.5  6.5  DR    4.5  DR   DR
                           7  0  4  .  5  4  .  5  D  R  4  .  5  D  R  D  R  4  .  5  D  R  D  R  4  .  5  D  R  D  R  D  R  D  R  D  R
                           20    4.5   6.5  DR   4.5   6.5  DR   4.5  DR    DR   4.5  DR   DR    4.5  DR   DR
                           30    4.5   6.5  DR   4.5  DR    DR   4.5  DR    DR   4.5  DR   DR    4.5  DR   DR
           140     120
                           50    4.5   DR   DR   4.5  DR    DR   DR   DR    DR   DR   DR   DR    DR   DR   DR
                           7  0  4  .  5  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R  D  R
         For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.
         DR = Design Required.
         a. Design assumptions:
            Maximum deflection criteria: L/240.
            Maximum roof dead load: 10 psf.
            Maximum roof live load: 70 psf.
            Maximum ceiling dead load: 5 psf.
            Maximum ceiling live load: 20 psf.
            Wind loads based on Table R301.2 (2).
            Strength axis of facing material applied vertically.