Page 382 - 2018_IRC
P. 382
WALL CONSTRUCTION
SIP WALL
CONTINUOUS
SEALANT EACH
SIDE
2x SOLE PLATE
MATCHING THE SIP
CORE THICKNESS
8d COMMON
NAILS AT 6 IN.
O.C. EACH SIDE
CAPILLARY BREAK
BETWEEN SIP AND
FOUNDATION
CONCRETE OR
MASONRY
FOUNDATION
WALL OR SLAB FOUNDATION ANCHORAGE
PER SECTION R403.1.6
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
FIGURE R610.5.2
SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
8d NAILS AT 6 IN. O.C. EACH SIDE
FACING
CONTINUOUS SEALANT
EACH SIDE
SIP SCREW AT 24 IN.
O.C.
CORE
8d NAILS AT 6 IN. O.C.
CONTINUOUS SEALANT EACH SIDE
EACH SIDE
For SI: 1 inch = 25.4 mm.
FIGURE R610.5.4
SIP CORNER FRAMING DETAIL
2018 INTERNATIONAL RESIDENTIAL CODE ® 357
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.