P. 380
WALL CONSTRUCTION
ROOF SHEATHING
WOOD ROOF TRUSS OR
CONVENTIONAL RAFTER AND
CEILING JOIST
CAP/TOP PLATE
CONNECTION 16d
SOLID BLOCKING
COMMON NAILS AT
16 IN. O.C.
ATTACH PER CODE
CAP PLATE
TOP PLATE
CONTINUOUS SEALANT 8d COMMON NAILS AT
EACH SIDE OF FRAMING 6 IN. O.C. EACH SIDE
AS RECOMMENDED BY
MANUFACTURER
CONTINUOUS
SEALANT
SIP WALL PANEL
For SI: 1 inch = 25.4 mm.
Note: Figure illustrates SIP-specific attachment requirements. Other connections shall be made in accordance with Tables R602.3(1) and (2), as appropriate.
FIGURE R610.5(3)
TRUSSED ROOF TO TOP PLATE CONNECTION
SIP WALL
SOLE PLATE CONNECTION IN
ACCORDANCE WITH TABLE
R602.3(1)
CONTINUOUS SEALANT
EACH SIDE
FLOOR SHEATING AND
2x SOLE PLATE FRAMING IN ACCORDANCE
MATCHING THE SIP WITH SECTION R502
CORE THICKNESS
8d COMMON NAILS AT 6
IN. O.C. EACH SIDE
RIM BOARD
FLOOR JOIST
CAP PLATE
8d NAILS AT 6 IN.
O.C. EACH SIDE
INSULATION
CONTINUOUS SEALANT
EACH SIDE
TOP PLATE
SIP WALL
For SI: 1 inch = 25.4 mm.
Note: Figure illustrates SIP-specific attachment requirements. Other connections shall be made in accordance with Tables R602.3(1) and (2), as appropriate.
FIGURE R610.5(4)
SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
2018 INTERNATIONAL RESIDENTIAL CODE ® 355
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.