Page 528 - 2018_IRC
P. 528

CHAPTER 14

                     HEATING AND COOLING EQUIPMENT AND APPLIANCES




             User notes:
                About this chapter: Chapter 14 addresses the indoor environmental control systems and appliances typically found in dwelling units. Cover-
                age includes general requirements for equipment and appliance sizing, condensate disposal, access and support, and specific coverage for
                more than a dozen different types of space conditioning equipment and appliances common to dwelling units.
                Code development reminder: Code change proposals to this chapter will be considered by the IRC—Plumbing/Mechanical Code Develop-
                ment Committee during the 2018 (Group A) Code Development Cycle. See explanation on page iv.




                              SECTION M1401                       ports  and  foundations  shall  be  in  accordance  with  Section
                                 GENERAL                          M1305.1.3.1.
             M1401.1  Installation.  Heating  and  cooling  equipment  and  M1401.5 Flood hazard. In flood hazard areas as established
             appliances shall be installed in accordance with the manufac-  by  Table  R301.2(1),  heating  and  cooling  equipment  and
             turer’s instructions and the requirements of this code.  appliances  shall  be  located  or  installed  in  accordance  with
                                                                  Section R322.1.6.
             M1401.2 Access. Heating and cooling equipment and appli-
             ances shall be located with respect to building construction
             and other equipment and appliances to permit maintenance,
             servicing and replacement. Clearances shall be maintained to          SECTION M1402
             permit cleaning of heating and cooling surfaces; replacement       CENTRAL FURNACES
             of  filters,  blowers,  motors,  controls  and  vent  connections;  M1402.1 General. Oil-fired central furnaces shall conform
             lubrication of moving parts; and adjustments.        to  ANSI/UL  727.  Electric  furnaces  shall  conform  to  UL
                                                                  1995.
               Exception: Access shall not be required for ducts, piping,
               or other components approved for concealment.      M1402.2 Clearances. Clearances shall be provided in accor-
                                                                  dance  with  the  listing  and  the  manufacturer’s  installation
             M1401.3  Equipment  and  appliance  sizing.  Heating  and  instructions.
             cooling  equipment  and  appliances  shall  be  sized  in  accor-
             dance with ACCA Manual S or other approved sizing meth-  M1402.3 Combustion air. Combustion air shall be supplied
             odologies based on building loads calculated in accordance  in  accordance  with  Chapter  17.  Combustion air  openings
             with ACCA Manual J or other approved heating and cooling  shall be unobstructed for a distance of not less than 6 inches
             calculation methodologies.                           (152 mm) in front of the openings.

               Exception: Heating and cooling equipment and appliance
               sizing shall not be limited to the capacities determined in         SECTION M1403
               accordance with Manual S where either of the following          HEAT PUMP EQUIPMENT
               conditions applies:
                                                                  M1403.1  Heat  pumps.  Electric  heat  pumps  shall  be  listed
                  1. The specified equipment or appliance utilizes multi-  and labeled in accordance with UL 1995 or UL/CSA/ANCE
                    stage technology  or variable refrigerant flow tech-  60335-2-40.
                    nology and the loads calculated in accordance with
                    the approved heating and cooling calculation meth-
                    odology are within the range of the manufacturer’s             SECTION M1404
                    published capacities for that equipment or appliance.  REFRIGERATION COOLING EQUIPMENT
                  2. The  specified  equipment  or  appliance  manufac-  M1404.1 Compliance. Refrigeration cooling equipment shall
                    turer’s published capacities cannot satisfy both the  comply with Section M1411.
                    total  and  sensible  heat  gains  calculated  in  accor-
                    dance with the approved heating and cooling calcu-
                    lation methodology and the next larger standard size           SECTION M1405
                    unit is specified.                                       BASEBOARD CONVECTORS

             M1401.4 Outdoor installations. Equipment and appliances  M1405.1  General.  Electric  baseboard  convectors  shall  be
             installed  outdoors  shall  be  listed  and  labeled  for  outdoor  installed in accordance with the manufacturer’s instructions
             installation. Supports and foundations shall prevent excessive  and Chapters 34 through 43. Electric baseboard heaters shall
             vibration,  settlement  or  movement  of  the  equipment.  Sup-  be listed and labeled in accordance with UL 1042.



             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                               503
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   523   524   525   526   527   528   529   530   531   532   533