Page 635 - 2018_IRC
P. 635

FUEL GAS



           4. Floor construction. Floor furnaces shall not be installed  accordance with this code. Fire dampers shall not be installed
              in concrete floor construction built on grade.   in clothes dryer exhaust duct systems.
           5. Thermostat. The controlling thermostat for a floor fur-  G2439.3  (614.4)  Exhaust  installation.  Exhaust  ducts  for
              nace shall be located within the same room or space as  clothes dryers shall terminate on the outside of the building
              the floor furnace or shall be located in an adjacent room  and shall be equipped with a backdraft damper. Screens shall
              or space that is permanently open to the room or space  not be installed at  the duct termination.  Ducts  shall not  be
              containing the floor furnace.                   connected or installed with sheet metal screws or other fas-
         G2437.3 (609.3) Bracing. The floor around the furnace shall  teners that will obstruct the flow. Clothes dryer exhaust ducts
         be braced and headed with a support framework designed in  shall not be connected to a vent connector, vent or chimney.
         accordance with Chapter 5.                           Clothes dryer exhaust ducts shall not extend into or through
                                                              ducts or plenums. Clothes dryer exhaust ducts shall be sealed
         G2437.4 (609.4) Clearance. The lowest portion of the floor  in accordance with Section M1601.4.1.
         furnace shall have not less than a 6-inch (152 mm) clearance
         from  the  grade  level;  except  where  the  lower  6-inch  (152  G2439.3.1 (614.4.1)  Exhaust  termination  outlet  and
         mm) portion of the floor furnace is sealed by the manufac-  passageway. The passageway of dryer exhaust duct termi-
         turer to prevent entrance  of water, the  minimum clearance  nals  shall  be  undiminished  in  size  and  shall  provide  an
                                                                                                             2
         shall be not less than 2 inches (51 mm). Where such clear-  open area of not less than 12.5 square inches (8065 mm ).
         ances cannot be provided, the ground below and to the sides  G2439.4  (614.5)  Dryer  exhaust  duct  power  ventilators.
         shall be excavated to form a pit under the furnace so that the  Domestic dryer exhaust duct power ventilators shall be listed
         required clearance is provided beneath the lowest portion of  and labeled to UL 705 for use in dryer exhaust duct systems.
         the furnace. A 12-inch (305 mm) minimum clearance shall  The dryer exhaust duct power ventilator shall be installed in
         be provided on all sides except the control side, which shall  accordance with the manufacturer’s instructions.
         have an 18-inch (457 mm) minimum clearance.
                                                              G2439.5 (614.6) Makeup air. Installations exhausting more
         G2437.5  (609.5)  First-floor  installation.  Where  the  base-  than 200 cfm (0.09 m /s) shall be provided with makeup air.
                                                                                3
         ment story level below the floor in which a floor furnace is  Where a  closet  is designed for the  installation of  a clothes
         installed  is  utilized  as  habitable  space,  such  floor furnaces  dryer, an opening having an area of not less than 100 square
         shall be enclosed as specified in Section G2437.6 and shall  inches (0.0645 m ) for makeup air shall be provided in the
                                                                             2
         project into a nonhabitable space.                   closet  enclosure,  or makeup air  shall  be  provided  by  other
                                                              approved means.
         G2437.6 (609.6) Upper-floor installations. Floor furnaces
         installed in upper stories of buildings shall project below into  G2439.6  (614.7)  Protection  required.  Protective  shield
         nonhabitable space and shall be separated from the nonhabit-  plates shall be placed where nails or screws from finish or
         able  space  by  an  enclosure  constructed  of  noncombustible  other work are likely to penetrate the clothes dryer exhaust
         materials. The floor furnace shall be provided with access,  duct. Shield plates shall be placed on the finished face of all
         clearance to all sides and bottom of not less than 6 inches  framing members where there is less than 1 / inches (32 mm)
                                                                                                 1
                                                                                                  4
         (152  mm)  and  combustion air  in  accordance  with  Section  between the duct and the finished face of the framing mem-
         G2407.                                               ber. Protective shield plates shall be constructed of steel, shall
                                                              have a minimum thickness of 0.062 inch (1.6 mm) and shall
                                                              extend not less than 2 inches (51 mm) above sole plates and
                       SECTION G2438 (613)                    below top plates.
                        CLOTHES DRYERS
         G2438.1 (613.1) General. Clothes dryers shall be tested in  G2439.7  (614.8)  Domestic  clothes  dryer  exhaust  ducts.
                                                              Exhaust ducts for domestic clothes dryers shall conform to
         accordance  with  ANSI  Z21.5.1/CSA  7.1  and  shall  be  the requirements of Sections G2439.7.1 through G2439.7.6.
         installed in accordance with the manufacturer’s instructions.
                                                                 G2439.7.1  (614.8.1)  Material  and  size.  Exhaust  ducts
                                                                 shall have a smooth interior finish and shall be constructed
                       SECTION G2439 (614)                       of metal not less than 0.016 inch (0.4 mm) in thickness.
                    CLOTHES DRYER EXHAUST                        The exhaust duct size shall be 4 inches (102 mm) nominal
                                                                 in diameter.
         G2439.1  (614.1)  Installation.  Clothes dryers  shall  be
         exhausted in accordance with the manufacturer’s instructions.  G2439.7.2 (614.8.2) Duct installation. Exhaust ducts shall
         Dryer exhaust systems shall be independent of all other sys-  be supported at 4-foot (1219 mm) intervals and secured in
         tems and shall convey the moisture and any products of com-  place.  The  insert  end  of  the  duct  shall  extend  into  the
         bustion to the outside of the building.                 adjoining duct or fitting in the direction of airflow. Ducts
                                                                 shall not be joined with screws or similar fasteners that pro-
         G2439.2  (614.2)  Duct  penetrations.  Ducts  that  exhaust         1
         clothes dryers  shall  not  penetrate  or  be  located  within  any  trude more than  /  inch (3.2 mm) into the inside of the duct.
                                                                               8
         fireblocking, draftstopping or any wall, floor/ceiling or other  Where dryer exhaust ducts are enclosed in wall or ceiling
         assembly  required  by  this  code  to  be  fire-resistance  rated,  cavities, such cavities shall allow the installation of the duct
         unless such duct is constructed of galvanized steel or alumi-  without deformation.
         num of the thickness specified in the mechanical provisions  G2439.7.3  (614.8.3)  Transition  ducts.  Transition  ducts
         of  this  code  and  the  fire-resistance  rating  is  maintained  in  used to connect the dryer to the exhaust duct system shall