SANITARY DRAINAGE



         702.2 Underground building sanitary drainage and vent                    TABLE 702.3
         pipe. Underground building sanitary drainage and vent pipe           BUILDING SEWER PIPE
         shall conform to one of the standards listed in Table 702.2.  MATERIAL                STANDARD
                                                              Acrylonitrile butadiene styrene
                             TABLE 702.2                         (ABS) plastic pipe in IPS
            UNDERGROUND BUILDING DRAINAGE AND VENT PIPE          diameters, including Sched-
                  MATERIAL                STANDARD               ule 40, DR 22 (PS 200) and   ASTM D2661; ASTM F628;
                                                                                       ASTM F1488; CSA B181.1
         Acrylonitrile butadiene styrene                         DR 24 (PS 140); with a solid,
           (ABS) plastic pipe in IPS                             cellular core or composite
           diameters, including Schedule  ASTM D2661; ASTM F628;   wall
           40, DR 22 (PS 200) and DR 24  ASTM F1488; CSA B181.1   Acrylonitrile butadiene styrene
           (PS 140); with a solid, cellular                      (ABS) plastic pipe in sewer
           core or composite wall                                and drain diameters, including
                                  ASTM A74; ASTM A888;           SDR 42 (PS 20), PS 35, SDR   ASTM F1488; ASTM D2751
         Cast-iron pipe                                          35 (PS 45), PS 50, PS 100, PS
                                  CISPI 301
                                                                 140, SDR 23.5 (PS 150) and
         Copper or copper-alloy tubing   ASTM B75; ASTM B88; ASTM   PS 200; with a solid, cellular
          (Type K, L, M or DWV)   B251; ASTM B306                core or composite wall
         Polyethylene (PE) plastic pipe   ASTM F714                                    ASTM A74; ASTM A888;
         (SDR-PR)                                             Cast-iron pipe           CISPI 301
                                  ASTM F1412; ASTM F714;
         Polyolefin pipe                                                               ASTM C14; ASTM C76;
                                  CSA B181.3                  Concrete pipe            CSA A257.1M;
         Polyvinyl chloride (PVC)                                                      CSA A257.2M
           plastic pipe in IPS diameters,                     Copper or copper-alloy tubing  ASTM B75; ASTM B88;
           including Schedule 40, DR 22  ASTM D2665; ASTM F891;    (Type K or L)       ASTM B251
           (PS 200) and DR 24 (PS 140);  ASTM F1488; CSA B181.2
           with a solid, cellular core or                     Polyethylene (PE) plastic pipe  ASTM F714
           composite wall                                      (SDR-PR)
         Polyvinyl chloride (PVC)                             Polypropylene (PP) plastic pipe  ASTM F2736; ASTM F2764;
           plastic pipe with a 3.25-inch   ASTM D2949, ASTM F1488                      CSA B182.13
           O.D. and a solid, cellular core                    Polyvinyl chloride (PVC)
           or composite wall                                     plastic pipe in IPS diameters,
         Polyvinylidene fluoride   ASTM F1673;                   including Schedule 40, DR 22  ASTM D2665; ASTM F891;
           (PVDF) plastic pipe    CSA B181.3                     (PS 200) and DR 24 (PS 140);  ASTM F1488
                                                                 with a solid, cellular core or
         Stainless steel drainage   ASME A112.3.1                composite wall
           systems, Type 316L
                                                              Polyvinyl chloride (PVC)
         For SI: 1 inch = 25.4 mm.
                                                                 plastic pipe in sewer and drain
                                                                 diameters, including PS 25,
                                                                 SDR 41 (PS 28), PS 35, SDR   ASTM F891; ASTM F1488;
                                                                                       ASTM D3034; CSA B182.2;
                                                                 35 (PS 46), PS 50, PS 100,
         702.3 Building sewer pipe. Building sewer pipe shall con-  SDR 26 (PS 115), PS 140 and   CSA B182.4
         form to one of the standards listed in Table 702.3.     PS 200; with a solid, cellular
         702.4 Fittings. Pipe fittings shall be approved for installation  core or composite wall
         with the piping material installed and shall comply with the  Polyvinyl chloride (PVC)
         applicable standards listed in Table 702.4.             plastic pipe with a 3.25-inch   ASTM D2949, ASTM F1488
                                                                 O.D. and a solid, cellular core
         702.5 Temperature rating. Where the waste water tempera-  or composite wall
         ture will be greater than 140°F (60°C), the sanitary drainage
         piping material shall be rated for the highest temperature of  Polyvinylidene fluoride  ASTM F1673;
         the waste water.                                        (PVDF) plastic pipe   CSA B181.3
                                                              Stainless steel drainage
         702.6 Chemical waste  system. A  chemical waste system  systems, Types 304 and 316L   ASME A112.3.1
         shall be completely separated from the sanitary drainage sys-
         tem. The chemical waste shall be treated in accordance with  Vitrified clay pipe   ASTM C4; ASTM C700
         Section 803.2 before discharging to the sanitary drainage sys-  For SI: 1 inch = 25.4 mm.
         tem. Separate drainage systems for chemical wastes and vent
         pipes shall be of an approved material that is resistant to cor-
         rosion and  degradation for the concentrations of chemicals
         involved.
         702.7  Lead bends and traps. The wall thickness of lead
                                       1
         bends and traps shall be not less than  /  inch (3.2 mm).
                                        8

         60                                                                     2018 INTERNATIONAL PLUMBING CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.