ACOUSTI-CLEAR MOTORIZED Technical Data
                                     ®
               10 22 26 Operable Partitions




               ACOUSTI-CLEAR  MOTORIZED SERIES TECHNICAL DATA
                                      ®



               •  Acoustically rated glass wall system up to 51 STC  •   Smart Track technology, with programmable trolleys
               •  Motorized seal system for ultimate performance  and automatic panel positioning, makes panel
                                                                  storage almost foolproof
               •   Single panels are often used in multipurpose rooms,
                 exhibition halls, and commercial buildings where   •  May be fabricated to satisfy right angle turn layouts
                 maximum flexibility is required                •  Protector Series safety system available
               •   Suspension system incorporates the easy to operate   •  UL  certified polymer dispersed liquid crystal MorphGlas ™
                                                                    ®
                 switch and curve Smart Track ™                 •  Custom glass and RAL powder coating color options

               Modernfold Model
               Acousti-Clear  Motorized                           Flat Panels, Individual Operation
                            ®
               This specification along with product information and model details can be downloaded from www.modernfold.com
               SPECIFICATION - SECTION 10 22 26 (10650) OPERABLE PARTITIONS

               PART 1 - GENERAL                                   to attain no less than the STC rating specified.
                                                                  Provide a complete and unedited written test
               1.1 RELATED DOCUMENTS                              report upon request.
               A.  Drawings and general provisions of the Contract,   C.  Preparation of the opening shall conform to the
                  including General and Supplementary Conditions   criteria set forth per ASTM E557 Standard Practice
                  and Division 01 Specification Sections, apply to   for Architectural Application and Installation of
                  this Section.                                   Operable Partitions.
                                                                D.  Do not begin installation until permanent HVAC
               1.2 SUMMARY                                        systems are properly operating and building and
               A. Section Includes:                               temperature and humidity have stabilized.
                  1.  Manually operated and electronically      E. Reference Standards
                    activated, individual panel operable partitions      1. ADA – Americans with Disabilities Act.
                    with glass panels.                             2.  ANSI Z97.1 - Safety Glazing Materials Used in
               B. Related Sections include the following:           Buildings.
                  1.  Division 03 Sections for concrete tolerances      3.  ASTM C1036 - Standard Specification for Flat Glass.
                    required.                                      4.  ASTM C1048 - Heat-Treated Flat Glass—Kind HS,
                  2.  Division 05 Sections for primary structural   Kind FT Coated and Uncoated Glass.
                    support, including pre-punching of support      5.  ASTM E84 - Surface Burning Characteristics of
                    members by structural steel supplier per        Building Materials.
                    operable partition supplier’s template.        6.  ASTM E413 - Classification for Rating Sound Insulation
                  3.  Division 06 Sections for wood framing and      7.  CPSC 16 CFR 1201 - Safety Standard for
                    supports, and all blocking at head and jambs    Architectural Glazing Materials.
                    as required.                                   8.  NEMA LD3 - High Pressure Decorative Laminates.
                  4.  Division 09 Sections for wall and ceiling framing
                    at head and jambs.                          1.4 SUBMITTALS
                  5.  Division 26 Sections: Power supply, conduit,   A.  Product Data: Material descriptions, construction
                    wiring, and electrical connections.           details, finishes, installation details, and operating
                                                                  instructions for each type of operable partition,
               1.3 QUALITY ASSURANCE                              component, and accessory specified.
               A.  Installer Qualifications: An experienced installer   B.  Shop Drawings: Show location and extent of
                  who is certified in writing by the operable     operable partitions. Include plans, elevations,
                  partition manufacturer, as qualified to install the   sections, details, wiring diagrams, attachments
                  manufacturer’s partition systems for work similar in   to other construction, and accessories. Indicate
                  material, design, and extent to that indicated for   dimensions, weights, conditions at openings,
                  this Project.                                   and at storage areas, and required installation,
               B.  Acoustical Performance: Test operable partitions   storage, and operating clearances. Indicate
                  in an independent acoustical laboratory in      location and installation requirements for
                  accordance with ASTM E90 test procedure         hardware and track, including floor tolerances
                  and classibied in accordance with ASTM E413     required and direction of travel. Indicate blocking


               Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.  1