Page 19 - EMPHISS
P. 19
ISO FULL BLEED A3 420 X 297 MM N 1. Do not scale from this drawing, work to figured
NOTES
dimensions only.
2.
Dimensions are in metres unless stated
3. otherwise. The way the world moves. By design.
This drawing is based on UMC Architects plan
referenced 20454_T0300_Site Plan - CFF
Fit-out, dated 21/06/22
KEY
Site boundary
Visibility Splay (2.4m x 43m) based on
MfS design speed of 30mph
Proposed realigned fence boundary
OVERVIEW PLAN
Existing public highway trees/shrubs to
be cut back and lowered to 0.6m in line
with visibility splay
Private land between the site boundary
and proposed realigned fence to have
low level planters/shrubs at 0.6m high
ABBEY ROAD
COMMERCIAL LOADING YARD
SLOW
WAY
2.40 Loading bays for 16.5m Articulated
Vehicle (Dynamic dock leveller)
Electric Sliding Gate
8m bay for Panel vans
Sliding Gate
Electric charging points x 5
Bin Store
Bin
Store
CAR PARK LOCATION PLAN
Standard bays x 13
Provision for vehicle 6135
wash down Accessible bays x 3
Canopy above van spaces
42180 Cycle Shelters
5no van charging points 16 No. Car Parking (Inc. 3no accessible - 16no electric charging spaces) Electric charging points x 16
2 No. Loading Docks
JT
6 No. Level Access Doors D C 22/06/22 Background updated AD FC KD
PS
JT
08/03/22
Site layout updated
5 No. Vans B 06/08/21 Layout Revised AT IH YS
Canopy above A 30/03/21 First Issue PS IH DHG
van access doors DRN CHKD APRVD
Double Stacked REV DATE REVISION DESCRIPTION / DETAILS BY BY BY
Cycle Shelters
CLIENT:
1500 .\Option 1\TFT Consultants Logo.png
JOB TITLE:
291 ABBEY ROAD
DRAWING TITLE:
CAR PARK
GENERAL ARRANGEMENT
STATUS:
FOR INFORMATION
DRAWING NO: REV: SCALE AT A3:
M000859-2-1-DR-001 D 1:350
33845