Page 5 - The Gluckman Occasional Number Ten
P. 5

SofTouch applanation tonometer
        Optimophtho Precision Instruments
        Units  stamped  with  serial  numbers
        RZ7X0015K9201-RZ7X0015K9299

        Eyeball  pressure  testing  device  may
        adhere  to  cornea,  requiring  surgical
        removal.  Contact  manufacturer  for
        list of authorized repair centers.


                                        RecuperComfort Hospital Beds
                                        Procrustes  Products  (Offshore
                                        Division)
                                        Chassis model WATF99-002

                                        Controls  for  lowering  and  raising
                                        sections  of  bed  may  malfunction,
                                        becoming  frozen  in  the  “UP”
                                        direction. Patients in traction may
                                        be  at  risk  for  counterproductive
        sequelae.  Problem  has  been  identified  as  a  software  bug;  upgrades
        fixing  that  feature  of  the  bed  are  available  for  free  download  at
        www.procrustesproducts/help/upgrades.com.














        Drip Master Intravenous Therapy Peripheral Cannula
        Dao Chemical, PVC Products division
        Packages marked with factory ID DCDM03-42

        Manufacturing  defect  in  check  valve  may  permit  infiltration  and
        extravasation. Return unopened boxes to Dao Chemical ASAP, using
        P.O box number on www.ketzel-quattlelawfirm.com/liabililty/dao.