Page 545 - aREA ix eXHIBITS
P. 545
RANGE OF VARIABLES
VARIABLE RANGE
1. Tools and May include but not limited to:
equipment, Tools and equipment: 1.14 machine bolts
materials and 1.1 set of wrenches 1.15 wall-mount brackets
PPE 1.2 set of pliers 1.16 roof-mount bracket
1.3 extension ladder
1.4 set of hammer PPE:
1.5 set of ropes 1.17 body belt & strap
1.6 electric drill with different bits 1.18 hard hat/ helmet
of various sizes 1.19 set gloves
Materials: 1.20 goggles
1.7 set of guy grips/clips 1.21 safety shoes
1.8 set of guy anchors/ribbons 1.22 tool pouch
1.9 turnbuckle
1.10 tie wrap
1.11 sets of washer, bolts and nuts
1.12 guy wire
1.13 rubber cap
2. Relevant 2.1 homeowner’s association
authorities 2.2 house owners
2.3 building administrators
2.4 apartment lessor
3. Fixing 3.1 Fixing structures
structures and 3.1.1. Guy wire
devices 3.1.2. Guy ribbon
3.1.3. Guy anchor
3.1.4. Turnbuckle
3.2 Fixing devices
3.2.1. screw hooks
3.2.2. set of bolts, nuts and washers
3.2.3. machine bolts – straight
3.2.4. tex screws
3.2.5. wallmount / roofmount brackets
3.2.6. Color coded tapes (Serves as an identifier of
Company/Installer
4. Types of 4.1 Roof-mounted
installation 4.2 Wall-mounted
4.3 Special or customized installation
5. Appropriate 5.1 leadman/team leader
personnel 5.2 supervisor
6. Installation and 6.1 cable re-routing
design 6.2 as-built plan
amendments
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
TRAINING REGULATIONS – BROADBAND INSTALLATION (FIXED WIRELESS SYSTEM) NC II Page 21