Page 551 - aREA ix eXHIBITS
P. 551
RANGE OF VARIABLES
VARIABLE RANGE
1. Tools, equipment, May include but not limited to:
materials and Tools: Customer Premise
PPE 1.1 RJ45 crimper Equipment:
1.2 Blade cutter 1.17 radio antenna
1.3 Staple gun
1.4 Set of plierss Equipment:
1.5 Set of screwdrivers 1.18 computer with NIC
1.6 Hand drill w/ bits 1.19 surge suppressor
1.7 Hammer 1.20 service vehicle
1.8 Mallet
1.9 compass PPE:
1.10 Extension ladders (12 feet 1.21 body belt & strap
length) 1.22 hard hat/ helmet
Materials: 1.23 set gloves
1.11 cable tie 1.24 goggles
1.12 sealant 1.25 safety shoes
1.13 cable tag 1.26 tool pouch / holster
1.14 grounding wire (2.0mm, 1.27 safety cones/traffic
stranded) safety devices
1.15 grounding rod (1/2” by 20”
with clamp)
1.16 surge suppressor
2. Installation and 2.1 Configure CPE
configuration of 2.2 Conduct radio frequency (RF) survey
CPE 2.3 Check strength of received signal
2.4 Fix CPE to pole
2.5 Secure mounting
2.6 Layout cable
2.7 Provide drip loop and attach the cable properly to the wall of
the building either through conduit or staple wire
2.8 Install surge suppressor nearest to ground and provide drip
loop before inserting the cable inside the premise
2.9 Extend drop cable to computer
3. Equipment 3.1 surge suppressor
3.2 personal computer/laptop with network-interface card
4. Appropriate 4.1 cable installer / lead man
personnel 4.2 ground man / helper
5. Problems 5.1 For CPE connections
encountered 5.1.1. failure of equipment / factory defects
5.1.2. incompatibility of CPE standards
5.1.3. power failure/interruptions
5.2 For CPE configuration
5.2.1. defective browser
5.2.2. viruses
5.2.3. firewall settings
5.2.4. network problem
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
TRAINING REGULATIONS – BROADBAND INSTALLATION (FIXED WIRELESS SYSTEM) NC II Page 27