Page 77 - QR CIMAR LASER SCREED
P. 77

3                   Operation

3.1                 Control Panel

Overview

                    a

Control panel -     b                                  d a) LCD display
functions           c                                  e b) Grade button
                                                       f c) Left and right arrow buttons
                    007823_001                         c d) Up and down arrow buttons
                                                       d e) Status LED
                    LCD display
                    Grade button                                            f) Power button
                    Left and right arrow
                    buttons               Displays all required user information.
                    Up and down arrow     Press to start grade entry mode.
                    buttons               Press to display and move the cursor for grade entry.
                                          Press both simultaneously to enter the Rugby menu.
                    Power button          Press to change the grade displayed.
                    Status LED            Press both simultaneously to reset the grade value to
                                          zero.
                                          Press to turn on or off the Rugby.
                                          Indicates the level status of the Rugby.

3.2 Turning the Rugby on and off

Turning on and off  Press the Power Button to turn on or off the Rugby.

                    After turning on:
                    • The LCD display turns on and displays the current status of the Rugby.
                    • If set up within the +/-6° self-levelling range (horizontal or vertical), the Rugby

                        automatically levels to create an accurate horizontal plane of laser light.
                    • Once levelled, the head starts rotating and Rugby is ready for use.
                    • If activated, the H.I.Alert system becomes active 30 seconds after completing the

                        levelling. The H.I.Alert system protects the laser against changes in elevation
                        caused by movement or settling of the tripod.
                    • The self-levelling system and the H.I.Alert function continue to monitor the position
                        of the laser beam to ensure consistent and accurate work.

Rugby 870/880, Operation                  17