Page 95 - QR CIMAR LASER SCREED
P. 95

Temperature Sensi-                                                                                                                              For each change in temperature of ± 5°C (± 9°F) the Rugby
tivity Settings                                                                                                                                 870/880 returns to the level position to check if the change
                                                                                                                                                in temperature has led to a change of the main levelling
                                                                                                                                    007625_001  system.
                                                                                                                                                For a more sensitive unit, you can change the setting to
                                                                                                                                                ± 2°C (± 4°F) temperature change.

                                                                                                                                                Available intervals:
                                                                                                                                                • Temperature is checked every 5°C/9°F
                                                                                                                                                • Temperature is checked every 2°C/4°F

                  007626_001

                  Temperature Check
                  Settings screens

                  Relevelling process
                  When the Rugby is relevelling, the Temperature Check Wait screen is displayed. Wait
                  until the process is finished before using the laser again. The Status LED flashes to
                  indicate normal levelling.

Negative Grade -  007627_001                                                                                                                    007628_001
Enable/Disable
                  Temperature Check                                                                                                             If you want to prevent confusion when setting up the laser,
                  Wait screens                                                                                                                  you can disable the negative grade function on the Rugby.

                  007629_001                                                                                                                    • ON: Negative grade is enabled.
                                                                                                                                                • OFF: Negative grade is disabled.

                                                                                                                                                    When negative grade is disabled, only positive grade can
                                                                                                                                                    be entered in the direction of the arrow-shaped align-
                                                                                                                                                    ment marks on the top of the Rugby.

                                                                                                                                    007630_001  35

                                  Negative Grade screens

Rugby 870/880, Rugby 870/880 Menu
   90   91   92   93   94   95   96   97   98   99   100