Page 78 - ITALVIBRAS E-CATALOG
P. 78

VB-E                                                   The double-conical flange VB-E vibrators have been desig-
                                                                ned for use in industrial processes in environments with a
                                                                potentially explosive atmosphere, caused by gas and dusts,
                                                                in compliance with ATEX Directive (94/9/EC).
                                                                They are supplied without eccentric weights, which must be
                                                                realised and mounted by the Manufacturer of the vibrating
                                                                machine. In particular, these vibrators can be used in areas
                                                                1 and 2 (gas) and in areas 21 and 22 (dusts) according to the
                                                                layout and following features:

                                                                Category: II 2 GD

                                                                Level of protection: Ex e IIC T3/T4 Gb, 	
                                                                Ex tb IIIC T...°C Db

                                                                Temperature class: See table

                                                                EC certificate: LCIE 06 ATEX 6092 X

                                                                Zones of use: 1, 2, 21, 22

         Technical features                        Functioning                                          Ambient temperature
                                                   Continual service (S1) at maximum decla-             From -20°C to +40°C, on request it is
         Power supply                              red centrifugal force and electric power.            possible to have vibrators for maximum
         Three-phase voltage from 220V to 690V,                                                         ambient temperatures of +55°C in tempe-
         50Hz or 60Hz; suitable for use with an    Centrifugal force                                    rature class T3.
         inverter from 20Hz to the base frequency  Proportioned for a centrifugal force
         with constant torque load profile.        equal to 5000 Kgf. (49 KN), with eccentric           Vibrator thermal protection
                                                   weights not included, to be made by the              On request with PTC rated thermistor
         Polarity                                  user.                                                heat detectors 130°C (DIN 44081-44082).
         4 poles.                                                                                       Also on request thermistors with different
                                                   Mechanical protection                                temperatures and anti-condensation
         Conformity with European Directives       IP 66 according to IEC 529, EN 60529.                heaters.	
         Low Voltage 2006/95/EC,
         ATEX 94/9/EC.                             Protection against mechanical impacts                Fixing of the vibrator
                                                   IK 08 according to IEC 68, EN 50102.                 In all positions and therefore without
         Reference Regulations                                                                          restriction.
         IEC/EN 60079-0, IEC/EN 60079-7,           Insulation class
         IEC/EN 60079-31, EN 60034-1.              Class F (155°C).                                     Lubrication
                                                                                                        All vibrators are lubricated in the factory
         Controls                                  Tropicalization                                      and do not require further lubrication
         The components that affect protection     Standard with “drop by drop” trickle                 if used in normal operating conditions
         are 100% accurately controlled and        system.	                                             (”FOR LIFE” lubrication). In heavy duty
         recorded.                                                                                      operating conditions periodical re-lubri-
                                                                                                        cation may be applied.

         4 poles - 1500/1800 rpm

                 Description                                    Mechanical specifications                                    Electrical specifications

         Code  Type             Poles                     rpm               Centrifugal force  NWeight  Temp.  Temp.  Max input         Power
                                                   50 Hz 60 Hz           kg kN                    kg    class  class    power           rating
                                                                50 Hz 60 Hz 50 Hz 60 Hz                   (G)    (D)        W
                                                                                                                                           W

                                                                                                                      50 Hz  60 Hz  50 Hz            60 Hz

three-   6E1223 VB 15/2510-D-E  4 1500 1800 2500 2500 24.5 24.5 68                                      T3     150°C  1700   1800   1390             1480
  phase                                                                                                 T4            1220   1350   1030             1100

         6E1378 VB 15/5000E-LM  4 1500 1800 5000 5000 49.0 49.0 101 T3 135°C 3200 3700 2560 2800