VB-E The double-conical flange VB-E vibrators have been desig-
ned for use in industrial processes in environments with a
potentially explosive atmosphere, caused by gas and dusts,
in compliance with ATEX Directive (94/9/EC).
They are supplied without eccentric weights, which must be
realised and mounted by the Manufacturer of the vibrating
machine. In particular, these vibrators can be used in areas
1 and 2 (gas) and in areas 21 and 22 (dusts) according to the
layout and following features:
Category: II 2 GD
Level of protection: Ex e IIC T3/T4 Gb,
Ex tb IIIC T...°C Db
Temperature class: See table
EC certificate: LCIE 06 ATEX 6092 X
Zones of use: 1, 2, 21, 22
Technical features Functioning Ambient temperature
Continual service (S1) at maximum decla- From -20°C to +40°C, on request it is
Power supply red centrifugal force and electric power. possible to have vibrators for maximum
Three-phase voltage from 220V to 690V, ambient temperatures of +55°C in tempe-
50Hz or 60Hz; suitable for use with an Centrifugal force rature class T3.
inverter from 20Hz to the base frequency Proportioned for a centrifugal force
with constant torque load profile. equal to 5000 Kgf. (49 KN), with eccentric Vibrator thermal protection
weights not included, to be made by the On request with PTC rated thermistor
Polarity user. heat detectors 130°C (DIN 44081-44082).
4 poles. Also on request thermistors with different
Mechanical protection temperatures and anti-condensation
Conformity with European Directives IP 66 according to IEC 529, EN 60529. heaters.
Low Voltage 2006/95/EC,
ATEX 94/9/EC. Protection against mechanical impacts Fixing of the vibrator
IK 08 according to IEC 68, EN 50102. In all positions and therefore without
Reference Regulations restriction.
IEC/EN 60079-0, IEC/EN 60079-7, Insulation class
IEC/EN 60079-31, EN 60034-1. Class F (155°C). Lubrication
All vibrators are lubricated in the factory
Controls Tropicalization and do not require further lubrication
The components that affect protection Standard with “drop by drop” trickle if used in normal operating conditions
are 100% accurately controlled and system. (”FOR LIFE” lubrication). In heavy duty
recorded. operating conditions periodical re-lubri-
cation may be applied.
4 poles - 1500/1800 rpm
Description Mechanical specifications Electrical specifications
Code Type Poles rpm Centrifugal force NWeight Temp. Temp. Max input Power
50 Hz 60 Hz kg kN kg class class power rating
50 Hz 60 Hz 50 Hz 60 Hz (G) (D) W
W
50 Hz 60 Hz 50 Hz 60 Hz
three- 6E1223 VB 15/2510-D-E 4 1500 1800 2500 2500 24.5 24.5 68 T3 150°C 1700 1800 1390 1480
phase T4 1220 1350 1030 1100
6E1378 VB 15/5000E-LM 4 1500 1800 5000 5000 49.0 49.0 101 T3 135°C 3200 3700 2560 2800