Page 12 - QR CIMAR GROUT PUMP
P. 12
CSGP/TEESIN/MAN/01/15 Compile by CJ
5. Inspection, Maintenance, and Cleaning
5.1) General Checklists
It is recommended to conduct an inspection on grout pump before and after operation.
Parts Checklists to follow
Structure Inspect the general condition of the grout pump.
Frame Check for screws, misalignment or binding of moving parts, cracked, bent,
or broken parts, and any other condition that may affect the safe operation
of the grout pump. Do not use damaged equipment.
Maintenance Clean the grout pump after each use.
Storage Always store the grout pump in a clean, dry, safe location out of reach of
children and other unauthorized people.
CAUTION! All maintenance, service, or repairs not mentioned in this
manual must only be performed by a qualified service technician.
6. Troubleshooting
Problem Possible Cause Solution
The Pump does not work Clean outlet product
Outlet product line line
No pressure of the pump Clean inlet product
clogged line
Clogged product Replace suction
chamber
intake line
Replace O-Ring
There is a leakage in Refit quick release
the suction chamber. coupling.
O-Ring wore out
Loose fitting of
quick release
coupling
For technical questions, please call +65 - 66431213 11
For Products Enquiry, please call +65 - 67581211