Page 12 - QR CIMAR GROUT PUMP
P. 12

CSGP/TEESIN/MAN/01/15                                                         Compile by CJ

5. Inspection, Maintenance, and Cleaning

5.1) General Checklists
It is recommended to conduct an inspection on grout pump before and after operation.

Parts      Checklists to follow
Structure  Inspect the general condition of the grout pump.
Frame      Check for screws, misalignment or binding of moving parts, cracked, bent,
           or broken parts, and any other condition that may affect the safe operation
           of the grout pump. Do not use damaged equipment.

Maintenance Clean the grout pump after each use.

Storage    Always store the grout pump in a clean, dry, safe location out of reach of

           children and other unauthorized people.

CAUTION!               All maintenance, service, or repairs not mentioned in this

manual must only be performed by a qualified service technician.

6. Troubleshooting

Problem                  Possible Cause                                       Solution
The Pump does not work                                                             Clean outlet product
                          Outlet product line                                         line
No pressure of the pump                                                            Clean inlet product
                         clogged                                                       line

                          Clogged product                                         Replace suction
                                                                                       chamber
                         intake line
                                                                                   Replace O-Ring
                          There is a leakage in                                   Refit quick release

                         the suction chamber.                                          coupling.

                          O-Ring wore out

                          Loose fitting of

                         quick                    release

                         coupling

                         For technical questions, please call +65 - 66431213          11
                         For Products Enquiry, please call +65 - 67581211