Page 1187 - Workshop Manual - Aumark (BJ1051)
P. 1187

53-11
                                                          Battery-Battery

               3.     Specific gravity inspection
               Hint:
               The application of hydrometer please refers to “Chapter 53 Battery-Electrolyte, Preparation).
               The following is a comparison table measured by hydrometer

                   Specific gravity value              Judgment                          Treatment
                                                                             Adjust the specific  gravity by
                       Above 1.300                Wrong liquid is filled     deionized water (refer to “Chapter 53
                                                                             Battery-Electrolyte- Preparation”)
                      1.250  ~  1.280                    Good                Continue to use

                                                                             Charge   (refer  to  “Chapter  53
                      1.220  ~ 1.250                  Undercharge            Battery-Battery,  Application  and
                                                                             maintenance”)
                                                                             Initial charge and  then inspect (refer
                                                Over discharged or there is
                   Under 1.100  ~ 1.220                                      to “Chapter 53 Battery-Battery,
                                                       malfunction
                                                                             Application and maintenance”)
                                                                             Initial charge and  then inspect (refer
                Specific gravity difference of   The cell may be have malfunction   to “Chapter 53 Battery-Battery,
                   every cell is above 0.04
                                                                             Application and maintenance”)
               4.     Voltage inspection
               The following is a comparison table measured by digital multimeter

                         Voltage                       Judgment                          Treatment

                       Above 12.5 V                      Good                Continue to use
                                                                             Charge   (refer  to  “Chapter  53
                      11.5  ~ 12.5 V                  Undercharge            Battery-Battery,  Application  and
                                                                             maintenance”)
                                                                                                                   53
                                                                             Initial charge and  then inspect (refer
                                                 Over discharged or inside
                       Under 11.5 V                                          to “Chapter 53  Battery-Battery,
                                                      malfunction
                                                                             Application and maintenance”)