Page 354 - Workshop Manual - Aumark (BJ1051)
P. 354
04-210
Diagnosis- illumination
Diagnostic procedure
1. Checking harnesses
(a) Use a multimeter to measure resistance of harness between pins 1 of F101 and left outline
marker light F003.
(b) Use a multimeter to measure resistance of harness between pin 2 of left outline marker light
F003 and pin 3 of F101.
Resistance: ≤2Ω
(c) Use a multimeter to measure resistance of harness between pin 1 of left outline marker light
F003 and ground.
04 Resistance: >1MΩ
Are check results normal?
Yes > Replace bulb.
No > Repair or replace harnesses.