Page 354 - Workshop Manual - Aumark (BJ1051)
P. 354

04-210
                                                Diagnosis- illumination
          Diagnostic procedure

          1. Checking harnesses
          (a)    Use a multimeter to measure resistance of harness between pins 1 of F101 and left outline
                 marker light F003.
          (b)    Use a multimeter to measure resistance of harness between pin 2 of left outline marker light
                 F003 and pin 3 of F101.
                 Resistance: ≤2Ω
          (c)    Use a multimeter to measure resistance of harness between pin 1 of left outline marker light
                 F003 and ground.
   04            Resistance: >1MΩ
          Are check results normal?
          Yes > Replace bulb.
          No > Repair or replace harnesses.