MAINTENANCE DATA
Nominal voltage of the generator 13.5
Nominal voltage 120A
Rated rotating speed 6000rpm 03
Rotation mode Clockwise from the driving termination
Polarity Negative grounding
Voltage 12V
Output power 2.5kW
Coil resistance of the rotor 3~5Ω
Coil resistance of the stator 5~6Ω
Diameter of the rotor Standard value 14.2~14.4mm
shaft Limit value 12.8mm
Clearance of the pinion Standard value 0.5~2.0mm
on the starter
Out-of-round of the Standard value 0.05mm
armature surface Limit value 0.1mm
Diameter of the Standard value 29.4mm
armature Limit value 28.4mm
Insertion depth of the Standard value 0.5mm
armature slice mica Limit value 0.2mm
Height of the carbon Limit value 7.0mm
bush of the armature
TORQUE REQUIREMENTS
Fasteners N•m
The fixed bolts on the rectifier of the generator 6~8
Generator bracket bolt 20 ~24
Nuts on the binding post of the generator 21~25
The fixed bolts on the external shell of the starter 8~10
The fixed bolts of the electromagnetic switch 8~10
The fixed nuts of the magnetic field coil 14~16
The connecting nuts between the starting motor 18~20
and the connection of the power end
The fixed bolts of the starter 68~72