CO                                    The symptoms of exposure to low levels
                                    is a colourless,
                                    odourless gas
                                                       of CO can be similar to those of many
                                    which causes
                                    asphyxiation
                                    through
                                                       and flu. The most common symptoms
                 hypoxia. When inhaled, it combines    other conditions, such as food poisoning
                 with the oxygen in the red blood cells
                 to form carboxyhemoglobin. As the     include headache, nausea, dizziness,
                 concentration levels of CO increase,
                 it prevents the bloodstream’s         tiredness and confusion, stomach pain
                 remaining oxyhaemoglobin from         and shortness of breath
                 transferring oxygen to important
                 tissues, thus killing the living cells.
                   As CO affects one’s cognitive
                 abilities, it can incapacitate the victim   insufficiently audible, or if the   non-volatile memory after
                 without their knowledge. Any sudden   occupants are infirm, pregnant,   commissioning to enable better
                 exertion can cause collapse and,    children, heavy sleepers, intoxicated,   discrimination. This circuit was also
                 as a result, evacuation of the area   or have a hearing impairment.  capable of allowing for drift due to
                 becomes impracticable. The                                        temperature or age of the
                 symptoms of exposure to low levels   BRIDGING THE GAP             piezoelectric speaker and battery
                 of CO can be similar to those of many   To create viable, isolated scenarios for   within the CO detector.
                 other conditions, such as food   research and development, the siting   After packaging the second revision,
                 poisoning and flu. The most common   requirements for the alarms in   further tests were conducted and it
                 symptoms include headache, nausea,   accordance with BS EN 50292 were   was found that ringing caused by
                 dizziness, tiredness and confusion,   considered.                 multipath reflections and pulse
                 stomach pain and shortness of breath.   Based on these requirements, a   stretching, or narrowing caused by
                   It is currently advisable to mount   means of detecting the CO alarm   excessive reverberation were leading
                 domestic CO detectors at ceiling   effectively over a short range can be   to an increase in reaction time. To
                 level, away from dead spaces or   achieved through the use of a   overcome this, the software was
                 obstructions, for effective detection.   specially designed circuit comprising a   revised to counter the distortion and a
                 A compromise is normally necessary   microphone. The design was also   means of mechanical noise
                 between CO detectors being sited   focused around the most commonly   attenuation was designed to act as a
                 near potential sources of CO gas and   available types of CO detector that   filter to free up the processing power.
                 the alarm being loud enough to be   are approved to BS EN 50291 Type B,
                 heard throughout the building. Such   which are capable of generating a   QUALITY, SIMPLICITY
                 detectors are mainly battery     distinctive sound pattern.       AND SUSTAINABILITY
                 powered, enabling a simple low cost   A basic alarm detection circuit was   The device is installed in between the
                 installation and usually do not   created using minimum viable    appliance and electrical supply. In
                 require battery replacement during   resources to conduct further testing   most instances this can be achieved
                 their operational life.          where basic alarm characteristics   by removing the supply cable from a
                   When an integrated response level   were monitored.             typical outlet, such as a switched
                 is exceeded, the CO detector is    While this design allowed for the   fused spur, and installing it into the
                 operable to output an audible alarm,   responsiveness to be altered, it   power output of the CO interlock. A
                 which, at best, would alert the   became evident from initial field tests   new supply can then be installed from
                 occupant to take action in the form of   that the prototype was vulnerable to   the switched fused spur to the power
                 manual isolation of power to an   sustained noise.                input of the CO interlock.
                 electrically controlled appliance. Such   In order to improve the   In order to avoid false alarms, the
                 intervention is likely to expose the   discrimination of the sensor circuit,   CO interlock works by monitoring the
                 responsible person to a greater level   the introduction of a microcontroller   audio alarm characteristics of
                 of CO gas. By this time, the occupant   and software capable of sampling,   commonly used CO detectors. If the
                 may already be suffering from the   storing and referencing the key alarm   alarm is considered valid, then the
                 symptoms of low exposure, such as   characteristics from other noise   interlock disconnects the electrical
                 dizziness and confusion. Entering a   sources was required. However,   mains supply to an associated fuel
                 room in which the defective appliance   applying this to the current hardware   burning appliance. The interlock is
                 is located can elevate the symptoms,   design was not practical and further   usually close to the appliance and the
                 ultimately leading to unconsciousness,   revisions were required which called   CO detector must be appropriately
                 brain damage or death. If no isolation   for more research and development   located in the same area to provide
                 of the appliance can be safely   into electronics and software.   adequate protection, as required by
                 achieved, the appliance may continue   To give the microcontroller a very   BS EN 50292. It may also be possible
                 to operate and raise the concentration   high false alarm immunity, a new   that other interlinked CO detectors
                 of CO, which is capable of affecting   analogue alarm detection circuit was   could be used in other areas away
                 life in adjacent properties. This could   designed to lock itself to the   from the protected area, for example
                 occur when the building is       particular alarm characteristics and   in bedrooms.
                 unoccupied, if the alarm is      compare it to a copy stored in     In consideration of the environment,