                 VALVE CARE TOOLBOX










                 Josh Eades, Project Engineer for Pipelines Maintenance            between the ball valve closures,
                 Centre and YPPC 2018 finalist                                     allowing pressure-holding capability
                                                                                   on the ball (Cameron Valve and
                 THE PROBLEM OF inadequate sealing   review established the context of the   Measurement Group, 2009).
                 of buried large diameter mechanical   problem statement, which was required   The Cort valve has been worked on
                 ball valves has been identified over a   to confirm the direction of the project.   less for the identified problem when
                 number of sites throughout the UK and   This was achieved by understanding,   compared to the Cameron valve; this
                 has the potential to cause significant   analysing, and gathering information   could be due to the smaller number
                 risk to UK gas supplies.         from the following information sources,   of these valves within the network
                   This project aimed to research   gathered with the assistance of the   (Wilde, 2017).
                 a ‘toolbox’ of technologies for the   National Grid Network Engineering Team:  The Cameron T31 fully welded ball
                 wider gas transmission/distribution     T/PR/MAINT/5030 Work Procedure   valve, shown in Figure 2 (Cameron
                 industry capable of addressing a   for the functional check of critical   Valve and Measurement Group, 2009),
                 range valve maintenance issues, with   valves with inlet pressures above 7 Bar   operates in a similar way to the Cort
                 a particular focus on buried valves   (Richard Waine, 2017)       valve. The main difference being that
                 suffering from corrosion.           G19/T/085 The Safe Adaption of   the Cameron valve has provision for
                   This project was designed to identify   Blind Plugs on Ball Valve Sealant Port   sealant injection through side access
                 new ideas and then challenge their   Connections and Body Vent Cavity   ports, along with view ports that, if left
                 appropriateness using basic engineering   Connections (Tim Green, 2015)  open, can result in increased ingress
                 tools, producing a shortlist of potential     T/SP/V/6 Steel Valves for use with Natural   for contaminants (Cameron Valve and
                 solutions that can be used to overcome   Gas at normal operating pressures above   Measurement Group, 2009).
                 the identified problem statement.   7 bar (Kate Neary, 2016)
                   This ‘innovation hot-housing’     Kings Lynn Initial Site Assessment   Operating conditions
                 method enables the conceptualisation   (Richards, 2017)           From both the Richards and DNV
                 and evaluation of the most promising     Flooded Valve Stem Investigation (DNV   GL reports, along with the technical
                 concepts to be carried out, in an   GL, 2016)                     interviews, it is clear that the below
                 appropriate manner, without the     Cort C-B5 Trunnion Mounted Manual   ground valves mentioned within the
                 overheads of a full engineering design   (Robert Cort, August 2013)  report operate in similar conditions.
                 process. It also provides a work package     Cameron Type 31 Fully Welded Body   These conditions relate to the gas flow,
                 to carry out early-stage basic prototype   Ball Valve (Cameron Valve and   gas quality and operating temperatures.
                 testing in the field.             Measurement Group, 2009)        The main question arising from these
                   Throughout the project, over 90     Valve Investigations Questionnaire   separate sources of information
                 separate concepts and technologies   (Brown, 2017)                concerns actual ground conditions
                 were identified as providing potential     Valve Investigations Questionnaire   surrounding the valve, from PH levels
                 specific solutions to the challenges   (Wilde, 2017)              to the level of the ground water table.
                 identified. Using a number of different   A number of subsections were discussed:  In reviewing the above literature,
                 quantitative and qualitative techniques,                          it became apparent that the initial
                 26 concepts were shortlisted.    Types of valve design            problem statement had been previously
                   These have been split into three   The National Grid Gas Network   identified, resulting in a general
                 concept groups, aiming to address the   operates with two main types of ball   consensus that below ground ball valves
                 areas of:                        valve. These are Cameron and Cort.   “have a high risk of failing to operate on
                    Assessing the situation and current   The valves operate in a similar manner,   demand in sub-zero weather conditions
                  condition of the infrastructure  differing mainly in their design.   due to water in the valve stems that may
                    Cleaning the area of fouling    As part of the technical interviews,   free and prevent station and unit valves
                    Protecting the valve stem assemblies   it was discovered that National Grid   from operating.” (DNV GL, 2016)
                  for future use                  also operates Audco plug valves;   A report from Dr Graham Richards,
                   The next phase of the project was a   however these are not included within   of OGI Ground Water Specialists, on a
                 feasibility assessment to identify which   this project due to their above ground   site prone to previous operational valve
                 concepts would be appropriate for   application and no identified defects   issues, states that “ground water was
                 future field trials.             (Brown, 2017).                   seen within the bi-directional pipework
                                                    The Cort C-B5 ball valve shown in   pits up to a level of approximately
                 Preliminary literature review    Figure 1 (Robert Cort, August 2013),   300mm below the top of the concrete
                 The literature review focused on the   uses a three-piece, bolted body design,   surrounding the pits. This seemed
                 existing operational knowledge of   manufactured from ring rolled forgings.   to coincide with the level of standing
                 the subject in question, providing an   The cast or forged ball features an   water surrounding the maintenance
                 overview of the current findings and   integral and external trunnion, which   pits.” (Richards, 2017)
                 bringing into focus areas that have yet   turns within the bearing mountings.   Within the DNV GL Paper, it was
                 to be explored by current literature. The   The bearing retainers are located   reported that “Nine out of the fifteen