Page 172 - booklet draft
P. 172
Following electronic cards of WAG-7 and WAG-9 locomotives were
repaired in house by replacing the defective components.
Locomo
Equipmen tive Make Loco Attention paid Cost of the
t failed No. equipment
Type
Pulse transformer on
INVERTER
GDU of WAG 7 AAL 27787 GDU card defective, it 2,50,000 /-
was replaced with
SIV
rewound transformer.
Resistor of I-4 channel
INPUT
CARD of WAG 7 MEDH 28437 defective, resistor 65,000 /-
MPCS A replaced with good
one.
Reed relay (QCON) of
MCU MCU defective, it was
Card WAG 7 AAL 28706 replaced with good 4,50,000 /-
one.
PMI card of module
Power
module of WAG 9 BHEL 31346 defective, it was 18,00,000 /-
replaced with good
SR
one.
SID card of module
Power
module of WAG 9 BHEL 31969 defective, it was 18,00,000 /-
SR replaced with good
one.
IO Card Reed relay on I/O card
(URB512) WAG 9 BHEL 31730 defective, it was 75,000 /-
of VCU replaced with new one.
Defective capacitors
PS CARD WAG 9 MEDH 31557 (Sic-safco make) 65,000 /-
of SR A replaced with Keltron
make capacitors.
Repairing of 02 GDU
GDU 2,60,000/-
Cards WAG 9 AAL 32033 cards of AAL Auxiliary per card
converters
32326 Repairing of 02 EBVs of 3,50,000/-
EBV WAG 9 CCB & pneumatic system per unit
31427