                                        10 22 26 (10650)      MODEL 3050 PART 2 - PRODUCT SPECIFICATIONS

                                                               B. STC Rating:  The operable wall acoustical performance
      2.06 PERIMETER TRIM AND SEALS                                 rating shall be based on (select):
      A. Vertical Trim and Seals: Panels shall have Trimless vertical       1. Standard Steel Skins: with a standard rating of
           astragals containing fl exible vinyl seals and incorporate reversible             52 STC, or optional ratings of 46 STC, 50 STC or 56 STC.
           tongue-and-groove-type confi gurations for positive interlocking        (Note: Not available with optional Wood Veneer or High Pres-
           with adjacent panels. Vertical trim shall not be permitted on the    sure Laminate.)
           panel faces, resulting in a minimal groove appearance between         2. Optional Acoustical Substrate: with optional ratings of
           adjacent panels.                                             43 STC, 46 STC, 48 STC or  50 STC.
      B. Horizontal Top Trim and Seals: Top seals shall consist of fl exible
           vinyl sweep seals installed on both sides of the panel. The seals    2.09 PANEL ACCESSORIES
           shall consist of a compressed bulb between two (2) fi ngers of vinyl.    A. Accessories including Single Pass Doors, Keyed Cylinder
           Top seal shall be fi xed, providing continuous-contact fl exible vinyl              Locks, Concealed Door Closures, Room Viewers, Exit
           sealing against the bottom fl ange of the overhead track.       Signs, Dry Marker Writing Surfaces, Recessed Eraser
                                                                    Trays, Vision Lites, Tack Surfaces, and Pocket Doors
      C. Horizontal Bottom Trim and Seals: Bottom seals shall consist of         shall be compatible with other accessories and
           multiple fi ngers of fl exible vinyl for positive contact and sealing         options, furnished and installed by the operable wall
           with various fl oor surfaces. Bottom seal type shall be (select):       manufacturer as noted on submitted shop drawings.
           1. Standard Adjustable Bottom Seals: consisting of fi eld
               adjustable, continuous-contact vinyl sweep seals with 2” [50.8]    2.10  SAFETY DEVICES
               nominal height with 3/4" [19] of nominal adjustment.  A. Optional safety devices by Guardian Personnel Protection
      D. Horizontal and Vertical Panel Trim: All exposed panel trim and       System™. The following safety devices shall shut the
            hinges shall be of one (1) similar color (select):       operable wall off immediately and prevent any movement
                                                                    until the system is reset at the control box (select):
           1. Dark Bronze.                                          1. Lead Sensing Edge: consisting of a Lead Sensing Edge
           2. Grey.                                                     (approximately 5'-0" (1.52 m long)) located on lead edge
                                                                        of  the operable wall. Lead Sensing Edge shall be wired
      2.07 CLOSURE SYSTEMS
                                                                        to  a wireless transmitter when activated an alarm
      A. Initial Closure System: The lead panel (the fi rst panel exiting the             will sound and shut the operable wall system off
           stack) shall form a seal vertically against a rigid wall surface. The             immediately.
           initial closure shall be accomplished by an Adjustable-       2. Floor Pressure Mats: consisting of molded vinyl mats
           Compensating Closure containing two (2) continuous-contact,            (1/8" [3.18] thick) located in the pocket area and shall
           fl exible vinyl bulb seals installed along the vertical edge of the            shut the operable wall system off immediately if a person
           lead panel for positive compression against a rigid wall surface.             or object isplaced on mat. Floor mats shall only require 1
           Initial closure panel shall contain a fl ush pull handle on each side.           lb./ft.  (4.88 kg/m ) of pressure to activate.
                                                                                  2
                                                                        2
      B. Final Closure System: The fi nal closure panel (the last panel exiting         (Note: Mat sizes may require additional width to pocket area.)
           the stack) shall form a seal vertically against a rigid wall surface.
           Final closure shall be accomplished by a Half Panel that does not    2.11 TRACK SYSTEM
           require any attachment to the permanent wall. The Half Panel   A. Type H.D. Continuously Hinged / Electric Steel Track: The
           and its two (2) immediately adjacent panels will incorporate        Continuously Hinged / Electric Steel track running surface
           adjustable bottom seals, and the fi rst panel adjacent to the half              shall be made of cold-rolled, high carbon steel tread
           panel shall contain a fl ush pull handle. The type of fi nal closure         surfaces to facilitate ease of panel movement and
           panel shall be (select):                                 operation. Track system shall not require a panel guide to
                                                                    straighten out the wall system.
           1. Standard Manual Half Panel Pivot Closure: consisting
               of a Half Panel requiring manual activation when                 B.  The steel tread surface shall be contained within a
      extending or retracting the operable wall. A half              continuous structural track housing extruded from
               panel inter-lock switch shall prevent the operable wall                       aluminum, which prohibits deterioration caused by rust
      from being retracted until the half  panel and adjacent         or corrosion. The track housing shall  have a durable
               panel are partially folded.                           anodized clear satin fi nish, which resists scratching, color
      (Note: Minumum of fi ve (5) panels required for Manual Half Panel         fading and fl aking. The track housing shall utilize grooves
      Pivot Closure system.)                                         and interlocking steel pins for positive alignment of
                                                                     adjacent track sections, and shall be reinforced overhead
           2. Optional Automatic Half Panel Pivot Closure:           by a heavy-duty steel bracket made of hot-rolled,  3/ 8" [10]
               consisting of a Half Panel attached to a mechanical clo                      thick plate steel. Aluminum track housing shall include
      sure device with a 50 to 1  ratio worm gear and 1 H.P.         an integral nut slot to accept a hardened  steel square
               (.746 kw) electric motor allowing the  operable wall to                      nut to facilitate attachment of each steel all-rod and  splice
      extend or retract automatically.                               brackets to the overhead structural support.
      2.08 ACOUSTICAL PERFORMANCE
      A. Certifi cation: The operable wall shall have been tested in an
           independent acoustical testing laboratory in accordance
      with ASTM E 90 and ASTM E 413 test procedures.


                                                                                                                   4
                                                                                                                 04-18
                    Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com