Page 101 - Arch binder
P. 101
Operable Partitions
10 22 26 (10650) MODEL 3050 PART 2 - PRODUCT SPECIFICATIONS
B. STC Rating: The operable wall acoustical performance
2.06 PERIMETER TRIM AND SEALS rating shall be based on (select):
A. Vertical Trim and Seals: Panels shall have Trimless vertical 1. Standard Steel Skins: with a standard rating of
astragals containing fl exible vinyl seals and incorporate reversible 52 STC, or optional ratings of 46 STC, 50 STC or 56 STC.
tongue-and-groove-type confi gurations for positive interlocking (Note: Not available with optional Wood Veneer or High Pres-
with adjacent panels. Vertical trim shall not be permitted on the sure Laminate.)
panel faces, resulting in a minimal groove appearance between 2. Optional Acoustical Substrate: with optional ratings of
adjacent panels. 43 STC, 46 STC, 48 STC or 50 STC.
B. Horizontal Top Trim and Seals: Top seals shall consist of fl exible
vinyl sweep seals installed on both sides of the panel. The seals 2.09 PANEL ACCESSORIES
shall consist of a compressed bulb between two (2) fi ngers of vinyl. A. Accessories including Single Pass Doors, Keyed Cylinder
Top seal shall be fi xed, providing continuous-contact fl exible vinyl Locks, Concealed Door Closures, Room Viewers, Exit
sealing against the bottom fl ange of the overhead track. Signs, Dry Marker Writing Surfaces, Recessed Eraser
Trays, Vision Lites, Tack Surfaces, and Pocket Doors
C. Horizontal Bottom Trim and Seals: Bottom seals shall consist of shall be compatible with other accessories and
multiple fi ngers of fl exible vinyl for positive contact and sealing options, furnished and installed by the operable wall
with various fl oor surfaces. Bottom seal type shall be (select): manufacturer as noted on submitted shop drawings.
1. Standard Adjustable Bottom Seals: consisting of fi eld
adjustable, continuous-contact vinyl sweep seals with 2” [50.8] 2.10 SAFETY DEVICES
nominal height with 3/4" [19] of nominal adjustment. A. Optional safety devices by Guardian Personnel Protection
D. Horizontal and Vertical Panel Trim: All exposed panel trim and System™. The following safety devices shall shut the
hinges shall be of one (1) similar color (select): operable wall off immediately and prevent any movement
until the system is reset at the control box (select):
1. Dark Bronze. 1. Lead Sensing Edge: consisting of a Lead Sensing Edge
2. Grey. (approximately 5'-0" (1.52 m long)) located on lead edge
of the operable wall. Lead Sensing Edge shall be wired
2.07 CLOSURE SYSTEMS
to a wireless transmitter when activated an alarm
A. Initial Closure System: The lead panel (the fi rst panel exiting the will sound and shut the operable wall system off
stack) shall form a seal vertically against a rigid wall surface. The immediately.
initial closure shall be accomplished by an Adjustable- 2. Floor Pressure Mats: consisting of molded vinyl mats
Compensating Closure containing two (2) continuous-contact, (1/8" [3.18] thick) located in the pocket area and shall
fl exible vinyl bulb seals installed along the vertical edge of the shut the operable wall system off immediately if a person
lead panel for positive compression against a rigid wall surface. or object isplaced on mat. Floor mats shall only require 1
Initial closure panel shall contain a fl ush pull handle on each side. lb./ft. (4.88 kg/m ) of pressure to activate.
2
2
B. Final Closure System: The fi nal closure panel (the last panel exiting (Note: Mat sizes may require additional width to pocket area.)
the stack) shall form a seal vertically against a rigid wall surface.
Final closure shall be accomplished by a Half Panel that does not 2.11 TRACK SYSTEM
require any attachment to the permanent wall. The Half Panel A. Type H.D. Continuously Hinged / Electric Steel Track: The
and its two (2) immediately adjacent panels will incorporate Continuously Hinged / Electric Steel track running surface
adjustable bottom seals, and the fi rst panel adjacent to the half shall be made of cold-rolled, high carbon steel tread
panel shall contain a fl ush pull handle. The type of fi nal closure surfaces to facilitate ease of panel movement and
panel shall be (select): operation. Track system shall not require a panel guide to
straighten out the wall system.
1. Standard Manual Half Panel Pivot Closure: consisting
of a Half Panel requiring manual activation when B. The steel tread surface shall be contained within a
extending or retracting the operable wall. A half continuous structural track housing extruded from
panel inter-lock switch shall prevent the operable wall aluminum, which prohibits deterioration caused by rust
from being retracted until the half panel and adjacent or corrosion. The track housing shall have a durable
panel are partially folded. anodized clear satin fi nish, which resists scratching, color
(Note: Minumum of fi ve (5) panels required for Manual Half Panel fading and fl aking. The track housing shall utilize grooves
Pivot Closure system.) and interlocking steel pins for positive alignment of
adjacent track sections, and shall be reinforced overhead
2. Optional Automatic Half Panel Pivot Closure: by a heavy-duty steel bracket made of hot-rolled, 3/ 8" [10]
consisting of a Half Panel attached to a mechanical clo thick plate steel. Aluminum track housing shall include
sure device with a 50 to 1 ratio worm gear and 1 H.P. an integral nut slot to accept a hardened steel square
(.746 kw) electric motor allowing the operable wall to nut to facilitate attachment of each steel all-rod and splice
extend or retract automatically. brackets to the overhead structural support.
2.08 ACOUSTICAL PERFORMANCE
A. Certifi cation: The operable wall shall have been tested in an
independent acoustical testing laboratory in accordance
with ASTM E 90 and ASTM E 413 test procedures.
4
04-18
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com