Operable Partitions
                                                                 KWP-FOLD - TRIMMED PART 3 - EXECUTION
                                                10 22 26 (10650)


           3.01 INSPECTION                                         3.03 ADJUSTING AND CLEANING
           A. Proper and complete preparation of the moveable glass wall   A. The moveable glass wall panels and track system shall be
                system opening shall be by others in accordance with the        adjusted and cleaned in accordance with KWIK-WALL’s
                architectural drawings, KWIK-WALL’s shop drawings and        written instructions.
                ASTM E 557. Any deviation of the actual opening from these
                specifi cations shall be called to the attention of the architect   3.04 PROTECTION
                prior to the installation of the operable wall.
                                                                   A. The moveable glass wall panels shall be stored in the
           B. Defi ciencies in the moveable glass wall opening shall be corrected             stacked (retracted) position prior to acceptance by the
                by others prior to installation of the moveable glass wall system.       owner’s representative.

           3.02 INSTALLATION                                       3.05 DEMONSTRATION
           A. The moveable glass wall system shall be installed by   A. KWIK-WALL’s authorized distributor shall demonstrate
                KWIK-WALL’s authorized distributor.                     proper operation and explain proper and necessary
           B. The moveable glass wall shall be installed in accordance with                   maintenance requirements of the moveable glass wall
                KWIK-ALL’s written instructions, shop drawings and        system to the owner’s representative.
                ASTM E 557 installation guidelines.











                                         KWP-Fold PRODUCT SELECTION GUIDE




                                           Stack                Perimeter   Final Closure  Maximum  Maximum
                    Model     Operation  Arrangements  Glass     Trim and    Options  Panel Height  Wall Width
                                                                  Seals

                                                     Standard:
                                         Standard:              Standard:  **Standard:
                                        Center Stacked  Clear    Trimless   Fixed Pivot
                   KWP-Fold    Paired                Optional:               Panel      *10' - 0"  Unlimited
                               Panels              Etched, Smoked,                     (3.05 m)
                                                     Decorated,
                                                    Patterned or
                                                      Berman
                                                      editions
                **Pivot Panel may not be required. Consult your KWIK-WALL representative for proper confi guration.
























                                                                                                                   5

                      Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com  05-16