Page 200 - Arch binder
P. 200
Operable Partitions
10 22 26 (10650) KWP-FOLD - TRIMLESS STACK ARRANGEMENTS
Standard Center Stack
Panels shall be Center Stacked, consisting of panels stacking to the center of the wall's installed position.
Stack Depth* Pocket Width**
The overall depth of the stack area, as required for panel The width of the pocket is determined by the widest panel
storage, is dictated by the total number of panels in the in the wall run. For specifi cation purposes, assume the
wall system. KWIK-WALL’s KWP-Fold panels widest panel is 2'- / 16" [90 cm] maximum. Pocket width
11
3
require an average stack depth of 2 / 8" [60] per panel. To may be calculated as follows:
determine the stack depth, calculate as follows:
Panel Width + 7" [178]
1
3
Number of Panels x 2 / 8" [60] + 2 / 8" [54] + / 4" [18] (allows 3 / 2" [89] for hand clearance on each side)
3
1
*Note: Additional stack depth is required for wall systems
containing the following type of panels:
1
• Handle: 3 / 2" [89]
3
• Pivot Panel(s) Closure: 2 / 8" [60]
• Pocket Door(s): 6" [152]
**For wall systems that include Pocket Doors, please reference
KWIK-WALL’s "Variotec" brochure for pocket layout dimensions
and applications.
7
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com 05-16