KWV-Tec - TRIMMED PART 2
                                      Operable Partitions
                                      10 22 26 (10650)
                                                                                  GENERAL SPECIFICATION

                 system when it is setup in the extended position. The trail      2.10 CARRIER SYSTEMS
                 edge of the Fixed Pivot Panel shall contain a continuous
                 contact, fl exible rubber seal that interfaces with aluminum   A. Carrier Type:  Each individual panel shall be top supported by
                                                                                     5
                 Adjustable Wall Jamb. The wall jamb shall be permanently         two (2) carriers utilizing a  / 8” [16] diameter  pendant bolt. Each
                 mounted to a structural wall surface and is fi eld-adjustable         carrier shall consist of dual horizontal, permanently-lubricated,
                 to compensate for out-of-plumb conditions of the fi xed wall.        precision ground steel  bearings with high strength polymer tires
                 One (1) side of the fi nal closure panel shall contain a pull             as required for smooth and quiet operation.  Multi-Directional
                                                                                                 o
                 handle. (Refer to Part 2.05 "B.                   carriers shall be capable of negotiating 90 , “X”, “L”, and “T”
                 Pull Handle Finish".)                             intersections. As required for moving panels from storage
                                                                   location(s) to various installed positions.
        Note: Pivot Panel may not be required. Consult your KWIK-
        WALL representative for proper confi guration. See page 7 for   B. Carrier Size:  The carrier size shall be:
        details.                                                   1. Type 425 Multi-Directional Carrier: certifi ed to be capable of
                                                                       supporting up to 425 lbs. ( 193 kg ) of total live load weight
             2. Optional Fixed Swing Panel Closure: consisting of a panel            per panel
                 utilizing top pivot and bottom pivot that engages with a
                 self-closing unit containing a hold-open feature that is        2.11 SUSPENSION SYSTEMS
                 recessed fl ush into the fl oor allowing the panel to pivot 90 0
                  in one (1) direction and be used to affect the fi nal closure,        A. Mounting Systems:  The KWV-Tec TRIMMED track system
                 and provides access thru the moveable glass wall system         shall be supported by (select):
                 when it is setup in the extended position. The trail edge of             1. Standard Drop Rod Mount: consisting of steel drop
                 the Fixed Swing Panelshall contain a continuous-contact,                        rod brackets with drop rods, consisting of adjustable rods of
                                                                         3
                 fl exible rubber seal that interfaces with aluminum            grade 2,  / 8" [10] diameter threaded steel all-rod provided
                                                                      3
                 Adjustable Wall Jamb. The wall jamb shall be permanently             with  / 8" [10] serrated steel nuts.
                 mounted to a structural wall surface and is fi eld adjustable           2. Optional Direct Mount: consists of  / 8” [10] x 3” [76]
                                                                                              3
                 to compensate for out-of-plumb conditions of the fi xed wall.             lag screws for attachment to a level overhead structural
                 One (1) side of the fi nal closure panel shall contain a pull               (wood or steel) support.
                 handle. (Refer to Part 2.05 "B. Pull Handle Finish".)
                                                                                                         3
                                                                   3. Optional Drop Rod Bracket Mount: consisting of  / 8” [10]
        2.08 ACOUSTICAL PERFORMANCE                                    thick steel brackets mounted to top fl ange of track and
                                                                       supported with adjustable rods of grade 2,  / 8” [10]
                                                                                                    3
        A. Certifi cation:  The operable wall shall have been tested in an             diameter threaded steel all-rod provided with  / 8” [10]
                                                                                                       3
             independent acoustical testing laboratory in accordance with             serrated steel nuts.
             ASTM E 90 and ASTM E 413 test procedures.
        B. STC Rating:  The operable wall acoustical performance rating
             shall be based on (select):
             1. Standard acoustical substrate: with a standard rating of 35
                 STC

        2.08 PANEL ACCESSORIES
        A. Accessories including a Floor Guide Channel shall be
             compatible with other accessories and options, furnished by
             KWIK-WALL as noted on submitted shop drawings.
             1. Floor Guide Channel: consisting of a clear anodized extruded
                 aluminum channel that is recessed into the fl oor (fl ush with
                 fi nished fl oor) to provide additional stability to panels as
                 they are moved in and out of their storage location.

        2.09 TRACK SYSTEM
        A. The KWV-Tec TRIMMED glass wall track system shall
             be extruded from structural aluminum alloy, which prohibits
             deterioration caused by rust or corrosion. The aluminum track
             shall have a durable anodized clear satin fi nish, which resists
             color fading and fl aking. The track shall utilize grooves and
             interlocking steel pins for positive alignment of adjacent track
             sections.  The track joints shall be reinforced overhead by a
                                              3
             heavy-duty steel bracket made of hot-rolled,  / 8” [10] thick
             plate steel.  Aluminum track shall include an integral nut slot
             to accept a hardened steel square nut to facilitate attachment
             of each threaded steel all-rod and splice brackets to the
             overhead structural support.
        B. Track Size:  The track size shall be Type 425 Multi-Directional
             Aluminum Track: certifi ed to be capable of supporting up to
             425 lbs. ( 193 kg ) of total live load weight per panel.                                            4