Page 234 - Arch binder
P. 234

Operable Partitions
                                              10 22 26 (10650)  KWV-Tec - TRIMMED PART 3 - EXECUTION


         3.01 INSPECTION                                         3.03 ADJUSTING AND CLEANING
        A. Proper and complete preparation of the moveable glass wall   A. The moveable glass wall panels and track system shall be
             system opening shall be by others in accordance with the        adjusted and cleaned in accordance with KWIK-WALL’s
             architectural drawings, KWIK-WALL’s shop drawings and        written instructions.
             ASTM E 557. Any deviation of the actual opening from these
             specifi cations shall be called to the attention of the architect   3.04 PROTECTION
             prior to the installation of the operable wall.     A. The moveable glass wall panels shall be stored in the
        B. Defi ciencies in the moveable glass wall opening shall be corrected             stacked (retracted) position prior to acceptance by the
             by others prior to installation of the moveable glass wall system.       owner’s representative.

        3.02 INSTALLATION                                        3.05 DEMONSTRATION
        A. The moveable glass wall system shall be installed by   A. KWIK-WALL’s authorized distributor shall demonstrate
             KWIK-WALL’s authorized distributor.                      proper operation and explain proper and necessary
                                                                      maintenance requirements of the moveable glass wall
        B. The moveable glass wall shall be installed in accordance with
             KWIK-ALL’s written instructions, shop drawings and        system to the owner’s representative.
             ASTM E 557 installation guidelines.






                            KWV-Tec - TRIMMED ACOUSTICAL  PRODUCT SELECTION GUIDE


                                                                                                   Maximum
                    Model    Operation     Stack        Glass   Perimeter  Final Closure  Maximum  Wall Width
                                        Arrangements            Trim and    Options      Panel
                                                                  Seals                  Height
                    KWV-Tec    Individual   Standard:  Standard: Clear      *Standard:              Unlimited
                    Trimmed     Panels   Perpendicular  Optional:  Trimmed  Fixed Pivot   **10' - 6"
                                           Optional:    Writing               Panel      (3.2 m)
                                          Parallel or   Surface,             Optional:
                                         Remote Stack  Opaque,                Fixed
                                                      Sandblasted             Swing
                                                                              Panel
                  STC Rating   Panel      Maximum
                             Thickness   Panel Weight
                             (nominal)     Lb./ft2
                             1 7/16”      330 lb.
                     35      [36.5mm]     150kg.
                 *Pivot Panel may not be required. Consult your KWIK-WALL representative for proper confi guration.
                 ** Contact Kwik-Wall if additional height is required.
























                                                                                                                 5

                    Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com  05-18