Operable Partitions MODEL 3020 WT PART 2 - GENERAL SPECIFICATIONS
10 22 26 (10650)
2.01 ACCEPTABLE MANUFACTURER 2.05 FINISHES
A. Operable walls shall be Series 3000, Model 3020WT Individual A. Finish Material Type: Panel fi nish material shall be Class A
Panels / Multi-Directional Weight Transfer as manufactured by (except wood veneer) rated in accordance with ASTM E 84,
KWIK-WALL Company. consisting of (select):
1. Standard Vinyl: consisting of Type II, reinforced vinyl weighing
2.02 PANEL CONSTRUCTION 21 oz./lin. yd. (651 g/lin. m). Vinyl shall meet or exceed
A. Panel Dimensions: Standard panel dimension shall be a CCC-W-408A and CFFA-W-101-D quality standards.
nominal 4” [101.6] thick. 2. Optional Upgrade Fabric: consisting of fade and tear
resistant fabric that resists water-based stains weighing 13
B. Panel Frame: Steel frame shall be 16-gauge galvanneal steel, oz./lin. yd. (403 g/lin. m).
horizontal top cross member shall be minimum 12-gauge
galvanneal steel which meets or exceeds ASTM A 653 3. Optional Basics Carpet: consisting of acoustically absorbent,
requirements. Frame shall be all-welded construction with steel non-woven needle punch fi bers fused to prevent fraying and
unraveling of material weighing 28.5 oz./lin. yd.(884 g/lin.m).
corner supports and crossbracing reinforcement. Panel frame shall Basics Carpet shall achieve a minimum NRC rating of .20
be Class A rated, fi re retardant, non-combustible and non-corrosive (applied over gypsum substrate) in accordance with ASTM C
in accordance with ASTM E 84. 423.
C. Panel Skins: Panel skins shall be Class A rated (except Wood 4. Optional Upgrade Carpet: consisting of acoustically absorbent,
Veneer and High Pressure Laminate) in accordance with ASTM E non-woven needle punch fi bers fused to prevent fraying and
84. Panel skin material shall consist of (select): unraveling of material weighing 23 oz./lin. yd. (713 g/lin. m).
Upgrade Carpet shall achieve a minimum NRC rating of .25
1. Standard Steel Skins: consisting of minimum 22-gauge
tension-leveled galvanneal steel, pressure laminated to a (applied over gypsum substrate) in accordance with
structural acoustical backer and mechanically fastened to the ASTM C 423.
steel frame to form a rigid, unitized and structural panel.
5. Optional Wood Veneer: consisting of unfi nished fl at cut wood
2. Optional Acoustical Substrate: consisting of structural
acoustical substrate pressure laminated to both sides of the veneer laminated to 1/2" [12.7] thick particle board core. Veneer
steel frame to form a rigid, unitized and structural panel. shall be book / running matched within a panel, and vertically
edge banded if Trimless astragals are specifi ed.
3. Optional Wood Veneer: consisting of particle board core covered (Notes: Optional Class "A" rated particle board is available. Acoustical
with wood veneer and pressure laminated to both sides of the substrate STC ratings apply for Wood Veneer panel construction..)
steel frame to form a rigid, unitized and structural panel. 6. Optional High Pressure Laminate: consisting of general purpose
4. Optional High Pressure Laminate: consisting of particle board plastic laminate pressure bonded to 1/2" [12.7] particle board
core covered with general purpose plastic laminate and core.
Phenolic backer sheet, which is pressure laminated to both sides (Note: Acoustical substrate STC ratings apply for High Pressure
of the steel frame to form a rigid, unitized and structural panel. Laminate panel construction.)
MODEL 3020WT PRODUCT GUIDE
D. Panel Weight: Maximum panel weight shall be 5.9 – 12.9 Standard Steel Skin Construction
lb./ft.2 (29 – 63 kg/m2) depending on STC rating, size and
options selected. STC Panel Thickness Max. Panel Maximum Maximum
Rating (nominal) Weight lb./ft. 2 Panel Height Wall Width
2.03 OPERATION 46 4" [101.6] 8.5 (41 kg/m ) 24' - 2" [7.37] Unlimited
2
A. Operation shall be Individual Panels with a Multi-Directional 50 4" [101.6] 9.5 (46 kg/m ) 24' - 2" [7.37] Unlimited
2
o
track system that allows the panels to negotiate 90 “X”, “L” and
“T” intersections as required for movement of panels from 52 4" [101.6] 9.5 (46 kg/m ) 24' - 2" [7.37] Unlimited
2
storage location(s) to various installed positions. Panels shall
be top supported by two (2) carriers featuring dual horizontal 56 4" [101.6] 12.9 (63 kg/m ) 24' - 2" [7.37] Unlimited
2
precision bearings with high strength polymer tires riding on a
structural aluminum track. MODEL 3020WT PRODUCT GUIDE
Optional Acoustical Substrate Construction
2.04 STACK ARRANGEMENTS
STC Panel Thickness Max. Panel Maximum Maximum
A. Stack Type: Panel storage confi guration shall be (select): Rating (nominal) Weight lb./ft. 2 Panel Height Wall Width
1. Standard Perpendicular Stack: consisting of panels 43 4" [101.6] 5.9 (29 kg/m ) 16' - 2" [4.93] Unlimited
2
stacked perpendicular to the wall’s installed position.
46 4" [101.6] 6.6 (32 kg/m ) 16' - 2" [4.93] Unlimited
2
2. Optional Parallel Stack: consisting of panels stacked
parallel to the wall’s installed position. 48 4" [101.6] 7.5 (37 kg/m ) 16' - 2" [4.93] Unlimited
2
3. Optional Remote Stack: consisting of panels located
2
remotely from the wall’s installed position, as shown on 50 4" [101.6] 9.0 (44 kg/m ) 16' - 2" [4.93] Unlimited
submitted shop drawings. *Optional Wood Veneer or High Prerssure Laminate only available as Accoustical Substrate Construction.
** Estimated panel weights are for intermediate panels. Weight may vary due to substrate, size, or function of panel.
B. Stack Quantity: Panels shall be stored in separate stack areas Add 105 lbs [47kg] for pass door. Add 6 lbs [3kg] per lin ft height for expanders. Add 3.5 to 8 lbs [1.6 to 3.6kg] per lin
as required for panel storage. ft for track.
*** Standard features can be modifi ed, contact your Kwik-Wall distributor for the features you want.
*** Horizontal Splice: Heights over 14'2" [4.31] with Acoustical Substrate require a structural
3
splice.
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com 04-18
07-15