Page 6 - Zero Lot Line
P. 6
G F E D C B A
MO #2005001203 2018.05.22 2018.05.22 DATE
URBAN COEUR BRIDGER KANSAS CITY, MO 64110 ARCHITECT OF RECORD: DRAW ARCHITECTURE + URBAN DESIGN LLC 214 W 21ST ST, SUITE 200 KANSAS CITY, MO 64108 STRUCTURAL ENGINEER: LIA ENGINEERING 4808 LIBERTY STREET KANSAS CITY, MO 64112 KAW VALLEY ENGINEERING 8040 N. OAK TRAFFICWAY KANSAS CITY, MO 64118 ZERO LOT LINE - LOT 26 BEACON HILL OVERLOOK © 2018 DRAW ARCHITECTURE AND URBAN DESIGN LLC ALL DRAWINGS AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED , DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. ORIGINAL DRAWINGS SCALE TO 24" x 36" SHEET UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION. ISSUED FOR PERMIT ISSUED FOR PERMIT ROOF PLAN A101 Printed 7/5/2018 4:36:41 PM
OWNER: 4325 TROOST AVE T 816.457.1756 T 816.531.8303 F 816.531.8305 T 816.534.9542 CIVIL ENGINEER: T 816.468.5858 PRINCIPAL IN CHARGE D DAVISON PROJECT ARCHITECT D DAVISON PROJECT TEAM MEMBERS D HERRON J HARTMAN DOMINIQUE DAVISON RELEASE SCHEDULE RELEASE NO.
1 GENERAL NOTES 1. ALL DIMENSIONS TO EXTERIOR FACE. 2. COORDINATE AS NECESSARY WITH TRUSS MANUFACTURER. 3. MINIMUM R‐VALUE REQUIREMENTS LISTED ON G100. 4. COORDINATE ROOF PENETRATIONS WITH TRUSS MANUFACTURER AND ARCHITECT. 5. GUTTER AND DOWNSPOUT COLOR TO BE SELECTED BY ARCHITECT. 6. FLASHING AND DRIP EDGE COLORS TO BE SELECTED BY ARCHITECT. 7. CONTRACTOR TO VERIFY ATTIC VENTING. RIDGE VENT AND STRIP VENT LENGTH SPECIFIED ON DRAWINGS WAS CALCULATED FOR SPECIFIED PRODUCTS. IF ALTERNATE PRODUCTS ARE USED, CONTRACTOR TO PERFORM REQ'D CALCULATIONS. 1
R30 CEILING INSULATION IN LIMITED SPACE ABOVE BEDROOM PER R402 RECTANGLE DOWNSPOUT MINIMUM 9.1 LF TOTAL (4.5 LF ON BOTH SIDES) OF COR‐A‐VENT S‐400 SOFFIT STRIP PER IRC 2012 24" MINIMUM ICE BARRIER PER IRC 905.2.7.1 MINIMUM 34.5 LF TOTAL (17.25 LF ON BOTH SIDES) OF COR‐ A‐VENT S‐400 SOFFIT STRIP PER IRC 2012 RECTANGLE DOWNSPOUT TO GRAVEL BELOW 5" F‐STYLE GUTTER MOD‐BIT ROOFING, MINIMUM SLOPE
2 4' ‐ 6" SOFFIT VENT 17' ‐ 6" SOFFIT VENT 24' ‐ 2" 2
A7 A300
3 F10 A500 3
6" / 12" 1/4" / 12" 16' ‐ 3 1/2"
RIDGE VENT
EQ
6' ‐ 9 1/2"
EQ
D10 A500 8" / 12"
8" / 12" EQ 25' ‐ 8" RIDGE VENT EQ
4 4
8" / 12"
SOFFIT VENT
D7 A300 EQ 4' ‐ 6" 3' ‐ 2"
6.79 LF OF COR‐A‐VENT V‐300 RIDGE VENT PER IRC 2012. MINIMUM 9.1 LF TOTAL (4.5 LF ON BOTH SIDES) OF COR‐A‐VENT S‐400 SOFFIT STRIP PER IRC 2012 D10 A300 EQ 17' ‐ 6" SOFFIT VENT A10 A300 EQ
RECTANGLE DOWNSPOUT TO GRAVEL BELOW 24" MINIMUM ICE BARRIER PER IRC 905.2.7.1 RECTANGLE DOWNSPOUT 5" F‐STYLE GUTTER RECTANGLE DOWNSPOUT TO GRAVEL BELOW ROOF PLAN 1/4" = 1'‐0"
5 MINIMUM 25.6 LF OF COR‐A‐VENT V‐300 RIDGE VENT PER IRC 2012. MINIMUM 34.5 LF TOTAL (17.25 LF ON BOTH SIDES) OF COR‐A‐VENT S‐400 SOFFIT STRIP PER IRC 2012 RE: A4/A200 5
A5
6 6
7 7
8 8
9 9
10 10
G F E D C B A