G F E D C B A
MO #2005001203 2018.05.22 2018.05.22 DATE
URBAN COEUR BRIDGER KANSAS CITY, MO 64110 ARCHITECT OF RECORD: DRAW ARCHITECTURE + URBAN DESIGN LLC 214 W 21ST ST, SUITE 200 KANSAS CITY, MO 64108 STRUCTURAL ENGINEER: LIA ENGINEERING 4808 LIBERTY STREET KANSAS CITY, MO 64112 KAW VALLEY ENGINEERING 8040 N. OAK TRAFFICWAY KANSAS CITY, MO 64118 ZERO LOT LINE - LOT 26 BEACON HILL OVERLOOK © 2018 DRAW ARCHITECTURE AND URBAN DESIGN LLC ALL DRAWINGS AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED , DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. ORIGINAL DRAWINGS SCALE TO 24" x 36" SHEET UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION. ISSUED FOR PERMIT ISSUED FOR PERMIT REFLECTED CEILING PLANS A110 Printed 7/5/2018 4:36:44 PM
OWNER: 4325 TROOST AVE T 816.457.1756 T 816.531.8303 F 816.531.8305 T 816.534.9542 CIVIL ENGINEER: T 816.468.5858 PRINCIPAL IN CHARGE D DAVISON PROJECT ARCHITECT D DAVISON PROJECT TEAM MEMBERS D HERRON J HARTMAN DOMINIQUE DAVISON RELEASE SCHEDULE RELEASE NO.
1 GENERAL NOTES 1. ALL WALL LIGHTING HEIGHTS ARE TO BE COORD. WITH ARCHITECT. 2. ALL EXHAUST FANS ARE TO BE ON A TIMER. 3. LIGHTS IN WET AREAS ARE TO BE DAMP RATED. 4. PROVIDE IC RATED RECESSED LIGHT FIXTURES IN ALL AREAS ADJACENT TO INSULATION. 5. CONTRACTOR TO VERIFY LIGHTING FIXTURE COMPLIANCE WITH IRC, AND/OR ALL CURRENT APPLICABLE LOCAL CODES AND ORDINANCES. 6. MOUNT ALL OUTLETS AT STANDARD MOUNTING HEIGHT PER CODE, UNO. 7. PROVIDE QUANTITY AND SPACING AND ELECTRICAL INSTALLATION PER IBC, IRC, AND/OR ALL CURRENT APPLICABLE LOCAL CODES AND ORDINANCES. CONTRACTOR TO PROVIDE QUANTITY AND LOCATION TO MEET CODE. 8. COORDINATE ELECTIRCAL FIXTURES AND QUANTITIES WITH MECHANICAL OR PLUMBING CONTRACTORS. 9. CENTER FIXTURES IN ROOM, UNO. 10. CONTRACTOR TO VERIFY LUMINAIRE VOLTAGE WITH BRANCH CIRCUIT SUPPLYING POWER TO LUMINAIRE PRIOR TO ORDERING. 11. CONTRACTOR TO DETERMINE ROUGH‐IN HOUSING SPEC IN ORDER TO ENSURE COMPATIBILITY WITH MOUNTING CONDITION. 12. CONTRACTOR TO VERIFY COMPATIBILITY OF TRANSFORMERS FOR ALL LOW VOLTAGE LUMINAIRES WITH DIMMER CONTROLS. 13. CONTRACTOR TO VERIFY ALL FINISH OPTIONS FOR LUMINAIRE TRIMS, REFLECTORS, FLANGES, ETC WITH ARCHITECT. 14. 5/8" TYPE X GYP BD WALLS AND CEILING WITHIN GARAGE SPACE PER R302.6 RCP LEGEND 4" Recessed Can Light Exhaust Fan with Recessed Light
POSSIBLE SOFFIT OVER CABINETS TO ROUTE GYP BD CEILING @ 9'‐0", UNO TAMLYN REVEAL, 3/8" EXPOSED LIP W/ 1/2" OPEN REVEAL, ALIGN WITH VERTICAL WALL OF ADJACENT WALL
2 DUCTS TO VERTICAL SHAFT REVEALS OF ADJACENT 2
D10 A300 5' ‐ 9" SLOPED 6' ‐ 10" 1' ‐ 1" TAMLYN REVEAL, 3/8" EXPOSED LIP W/ 1/2" OPEN REVEAL, ALIGN WITH VERTICAL REVEALS TAMLYN J MOLD AT TERMINATION OF SLOPE AND AROUND COLUMN , REF. DETAILS
1' ‐ 6 3/4" SOFFIT 2' ‐ 4" 3 2' ‐ 9 3/4"
EQ
EQ EQ 3' ‐ 5"
2' ‐ 0" 6' ‐ 4"
3 A7 A300 3
3 2 2' ‐ 0"
4' ‐ 8"
8' ‐ 1" 1" / 12"
10' ‐ 8" 3' ‐ 5" 5' ‐ 0" 3' ‐ 3" 5' ‐ 5" 2
2' ‐ 0" 5' ‐ 2" 2' ‐ 8"
EQ EQ EQ
4 2 4
EQ
EQ
D7 A300 EQ 3' ‐ 0" EQ
HARDIE BOARD, SMOOTH, PAINTED, SLOPED HARDIE FASCIA BOARD
PROVIDE POWER FOR GARAGE DOOR OPENER GWB @ B.O STRUCT A.F.F. 8' - 4" POSSIBLE GYP BD SOFFIT, TBD, FOLLOWING FINALIZATION OF TRUSS GWB @ B.O STRUCT A.F.F. 8' - 4" POSSIBLE GYP BD SOFFIT, TBD, FOLLOWING FINALIZATION OF TRUSS A10 A300 RE: A4/A200
FIRST FLOOR 1/4" = 1'‐0"
5 DESIGN DESIGN 5
A5
R30 CEILING INSULATION IN LIMITED SPACE ABOVE BEDROOM PER R402
6 BEDROOM CEILING TO BE VAULTED ATTIC ACCESS LADDER PER R807, COORDINATE WITH TRUSS DESIGNER FOR ROUGH OPENING REQ'D. 6
3' ‐ 3" 1' ‐ 3" 2' ‐ 6"
2
EQ 2' ‐ 1 1/4"
7 7
A7 A300
EQ
5' ‐ 8"
2' ‐ 5 1/4"
2' ‐ 8"
1' ‐ 11"
2 4' ‐ 6" EQ
EQ
3' ‐ 3" SD 1' ‐ 11" EQ
2
8 8
4' ‐ 0" 7' ‐ 0" 7' ‐ 0" 7' ‐ 0"
4' ‐ 0" EQ
EQ
D7 A300 2
A10 A300
SECOND FLOOR 1/4" = 1'‐0"
D10 A300 RE: A4/A200
9 9
A9
10 10
G F E D C B A