Page 3 - Area 51 CDs
P. 3
03.29.2023
1 2) GENERAL CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL APPLICABLE CODES, MUNICIPAL ORDINANCES, AND BUILDING 3) THE CONTRACTOR SHALL INVESTIGATE ALL FIELD CONDITIONS AND SHALL PROMPTLY NOTIFY THE ARCHITECT OF ANY WHICH DO NOT AGREE WITH THOSE SHOWN IN THESE DRAWINGS. WORK AFFECTED BY DISCREPANCIES SHALL CEASE UNTIL THEY ARE 4) ALL SUBSTITUTIONS AND CHANGES TO THESE DRAWINGS MUST BE SUBMITTED TO THE ARCHITECT AND / OR OWNER FOR SUBCONTRACTORS ARE RESPONSIBLE TO OBTAIN ALL REQUIRED BUILDING PERMITS AND LICENSES AS REQUIRED BY THE MUNICIPALITY TO PERFORM CONSTRUCTION ACTIVITIES REQUIRED 6) THE CONTRACTOR SHALL BE HELD ENTIRELY RESPONSIBLE FOR SAFETY REGULATIONS, PROCEDURES AND POLICIES. 7) THIS WORK IS PRIMARILY FOR BUILDING PERMIT SUBMITTAL ONLY AND DOES NOT INCLUDE MEANS AND METHODS FOR CONSTRUCTION WHICH SHALL BE THE RESPONSIBILITY OF THE 8) ANY NEW ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL ELECTRIC CODE, SHALL BE INSTALLED AS INDICATED, AND SHALL BE PROPERLY 9) THE CONTRACTOR (AND SUBCONTRACTORS) SHALL MAINTAIN A CLEAN PROJECT SITE AND SHALL CLEAN UP ALL DEBRIS AND SURPLUS MATERIAL UPON COMPLETION OF THE JOB. 10) THE ARCHITECT WILL NOT HAVE CONTROL OF AND SHALL NOT BE RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS IN CONNECTION WITH THE WO
1) DO NOT SCALE DRAWINGS. REGULATIONS. RESOLVED. APPROVAL. 5) GENERAL CONTRACTOR AND HIS TO COMPLETE THIS WORK. GENERAL CONTRACTOR. GROUNDED AND SHIELDED. SHEET TITLE WALL CONSTRUCTION G002
ADHERED MASONRY OR STUCCO REINFORCING MESH CONTINUOUS INSULATION, DEDICATED DRAINAGE PLANE OF 3/16" MINIMUM SHALL BE PROVIDED KEENE 1/4" OR 10MM DRIWALL RAINSCREEN OR SIMILAR FULLY SEALED CONTINUOUS AIR AND WATER | 2220 project #
2 BASE COAT R-5 MIN. BARRIER SYSTEM
RE: G001 FOR Culp Residence 5308 W 65th PL PRAIRIE VILLAGE, KS 66202 BRIAN & JENNIFER CULP
NO SHEET MEMBRANE PERMITTED. PROVIDE STURDI-STRIPS @ 16" O.C. AND CORE-A-VENT AT TOP AND BOTTOM OF ALL COPING CAPS ARE TO TO BE A CUSTOM BENT PROFILE. COORDINATE WITH PROJECT 8/16/23 OWNER Architect
3 AIR/WATER RESISTIVE BARRIER: ZIP R6 INSULATED SHEATHING - ALL SHIPLAP AND PANEL SIDING WALL SYSTEMS SHIPLAP SYSTEM TO INCORPORATE PAINTABLE EASY TRIM E34 OUTSIDE CORNERS, EZ 28 WINDOW HEAD WITH EZ40 AT JAMBS AND SILL AND EZ48 FOLLOW MANUFACTURERS INSTRUCTIONS ON ALL PRODUCTS. EXTERIOR WALL TYPE MASONRY SEAL David Herron - Kansas License #A-3665
1/2" GYPSUM BOARD W/ #4 FINISH MIN. 1 COAT PRIMER 2 COAT LATEX PAINT CERTAINTEED SMART MEMBRANE VAPOR RETARDER 2x6 Framing @ 16" O.C. INSULATION TYPE PER OWNER, R-13 MIN., R-20 OR HIGHER RECOMMENDED (OPEN CELL SPRAY FOAM RECOMMENDED) NOTES: PENETRATION REQUIREMENTS - STARTER TRIM. THE ARCHITECT. 3" = 1'-0"
FIBER CEMENT OR PANEL SIDING RE: ELEVATIONS CONTINUOUS INSULATION, R-5 MIN. SYSTEM BARRIER SYSTEM
4 COR-A-VENT & STURDI STIP BATTEN FULLY SEALED CONTINUOUS AIR AND WATER REVISIONS
CRAWL SPACE c R-VALUE 10/13 S.W. Corner of 10th & Main
R-VALUE 10,2 ft RE: G001 FOR CIVIL ENGINEER Land Survey Company P.O. Box 528 Grandview, MO. 64030
SLAB d AND DEPTH
BASEMENT c WALL R-VALUE AIR/WATER RESISTIVE BARRIER: ZIP R6 INSULATED SHEATHING - PROVIDE STURDI-STRIPS @ 16" O.C. AND CORE-A-VENT AT TOP AND BOTTOM OF SHIPLAP SYSTEM TO INCORPORATE PAINTABLE EASY TRIM E34 OUTSIDE CORNERS, EZ 28 WINDOW HEAD WITH EZ40 AT JAMBS AND SILL AND EZ48 ALL COPING CAPS ARE TO TO BE A CUSTOM BENT PROFILE. COORDINATE WITH FOLLOW MANUFACTURERS INSTRUCTIONS ON ALL PRODUCTS.
5 15/19 NO SHEET MEMBRANE PERMITTED.
FLOOR R-VALUE 19 1/2" GYPSUM BOARD W/ #4 FINISH MIN. 1 COAT PRIMER 2 COAT LATEX PAINT CERTAINTEED SMART MEMBRANE VAPOR RETARDER 2x6 Framing @ 16" O.C. INSULATION TYPE PER OWNER, R-13 MIN., R-20 OR HIGHER RECOMMENDED (OPEN CELL SPRAY FOAM RECOMMENDED) NOTES: PENETRATION REQUIREMENTS - ALL SHIPLAP AND PANEL SIDING WALL SYSTEMS STARTER TRIM. THE ARCHITECT. EXTERIOR WALL TYPE SIDING 3" = 1'-0" LANDSCAPE ARCHITECT
MASS WALL R-VALUE i 8/13
WOOD FRAME WALL R-VALUE 20 or 13+5
6 GENERAL CONTRACTOR MADI MALI HOMES 1741 JEFFERSON STREET Kansas City, MO 64108 Ph: 816-214-6062 www.madimalihomes.com
CEILINNG R-VALUE 49
GLAZED FENESTRATION SHGC b,e .40 MECHANICAL ENGINEER
SKYLIGHT b U-FACTOR 0.55
Gray
7 R-49 INSULATION (RECOMMENDED OPEN CELL SPRAY FOAM)
and Mold Resistant Gypsum Backing Board][Cementitious Backer Units] (092900) at all stone and/or tile finish locations; and Mold-Resistant Gypsum Backing Board (092900) at interior face of exterior Provide sound-Attenuation blankets (092900) at all interior partitions surrounding private offices, sleeping areas, conference/assembly spaces, teaching/instruction areas, mechanical rooms, and any spaces housing mortorized equipment, unless All interior walls are 2x4 unless noted otherwise. Provide 2x6 walls at all pocket door locations. PARTITION SYSTEM GENERAL NOTES FENESTRATION U-FACTOR b 0.32 ROOF ASSEMBLY CONSTRUCTION: 60 Mil Fully Adhered TPO Membrane Color - Densdeck Cover Board 2” ThermalStar 25 EPS (R8.4) OR 2" POLYISO (R12) GAF SA Vapor Retarder XL (no primer) 3/4" ADVANTECH OSB ROOF DECK CERTAINTEED SMART MEMBRANE VAPOR RETARDER 5/8" GYPSUM BOARD - LEVEL 4 FINISH 2 COATS LATEX PAINT
Provide [Moisture- provide Moisture- walls, typ. noted otherwise. 1 1/2" = 1'-0" CLIMATE ZONE 2018 IECC -TABLE R402.1.2. 12" = 1'-0" EXTERIOR ¼” 1 COAT PRIMER - INTERIOR ROOF ASSEMBLY 3" = 1'-0" STRUCTURAL ENGINEER APEX ENGINEERS INC Kansas City, MO 64108 www.apex-engineers.com
1. 2. 3. 4. 4A PER ROOF TRUSS DESIGN 1625 Locust St. Ph: 816-421-3222
1
ARCHITECT OF RECORD herron + partners p.o. box 414986 Kansas City, Missouri 64111 phone: 816.832.4647 www.herronandpartners.com © 2023 david herron and partners, llc
8 herron + partners
F E D C B A