Page 163 - Clinical Manual of Small Animal Endosurgery
P. 163

Operative Laparoscopy  151






















                                          (a)





















                                          (b)

                                  Fig. 5.11  (a) The Endo Stitch device uses a needle with suture swaged in
                                  the centre (arrow). The needle is secured in one jaw of the instrument.
                                  (b) The jaws are closed around the tissue and the needle is passed to the
                                  other jaw by a toggle switch on the handle of the instrument.



                                  animal is positioned in 30° left oblique recumbency and prepared for
                                  aseptic  surgery.  Following  insertion  of  the  endoscope,  the  stomach  is
                                  inspected and distended with air from the endoscope. The abdominal
                                  wall is palpated with forceps while the pyloric antrum is viewed to iden-
                                  tify the site for gastropexy. Once the correct orientation of the antrum
                                  to the body wall is obtained, two stay sutures are placed. A large needle
                                  is passed percutaneously caudal to the thirteenth rib through the body
                                  wall and into the antrum of the stomach while viewing with the endo-
                                  scope. The needle is passed back out through the skin and secured with
                                  haemostatic  forceps.  A  second  suture  is  placed  in  the  same  manner