Page 11 - Microsurgery
P. 11

The suturing of the vein graft is performed using an Ikuta clamp, which allows the vessel to
               be flipped and facilitates the approximation of the two vein segments via a sliding rail
               mechanism on the clamp's two branches. Two simple clamps are also used to interrupt
               proximal and distal blood flow.