Page 12 - PIGNAT catalogue 2020 GB_092020
P. 12

MINI UNITS





                                              ELA/100    STIRRED LIQUID - LIQUID EXTRACTION


                                               ➢    Liquid-Liquid extraction process in a stirred column

                                               Study of the process of liquid-liquid extraction
                                               Identification of the operating conditions
                                               Determination of the interphase level

                                               Apply a ternary phase diagram
                                               Material balance
                                               Determination of the efficiency of the HUT / NUT column



                                                       General specifications   •  Glass decanter with heavy phase outlet, light
                                                                                 phase feeding, draining column.
                                              •  2 polyethylene storage tank.
                                                                                •  Inter-phase  level  setting  system  by  lateral
                                              •  2  self  priming  peristaltic  pump,  variable   crosshead, setting from the ground.
                                                speed.

                                              •  Glass decanter with light phase outlet, heavy
                                                phase feeding.

                   Other extraction pilots
                                              •  Glass column.
                                                    www.pignat.com
            ELA/3000 Stirred liquid - liquid extraction
                                                  www.pignat.com
            ELL/4000 Pulsed liquid - liquid extraction
                                              •  Stirring device, composed of Ss Rushton type            100 - 240 V
                                                stirrer, variable frequency motor.                       1ϕ - 50/60 Hz
                                                                                          Dim: 105 x 65 x 135 cm  -  60 kg




                  LIQUID-EXTRACTION MIXER SETTLER  ELM/2000


                           ➢     Study a liquid-liquid extraction in mixer settlers



                                    Continuous liquid-liquid extraction process study

                                              Identification of the operating conditions

                                                        Ternary diagram using

                                                               Mass balance
                                   Determination of the efficiency of the HUT / NUT column




                 General specifications
                                         •  Polyethylene storage tank, 30L with draining
        •  3 polyethylene storage tanks.   valve.

        •  3 peristaltic pumps.

        •  Stirrer with speed display, SS mobile.

        •  Horizontal settler with :
              Mixing  zone  with  separation  and
              overflow.
              Settling  zone  with  light  phase  over
              flow, heavy phase draw-off , sample.
                                                           100 - 240 V
                                                                   Ventilation
                                                          1ϕ - 50/60 Hz

        •  Stirrer with speed display. SS mobile.   Dim : 130 x 70 x 100 cm  -  100 kg
         12                                                           Chemical engineering & unit operations
   7   8   9   10   11   12   13   14   15   16   17