Page 104 - Vessel Sanitation Program 2018 Operations Manual
P. 104
VSP 2018 Operations Manual
ACTIVITY POOLS and INTERACTIVE RWFs that can be
HEATED by the sun and/or exterior temperature.
Batch halogenation of the tub and compensation tank may help
in reaching the minimum 10 ppm residual quickly.
Facilities filled only with seawater are exempt from this
requirement.
6.4.2.1.3 Records (10)
A written or electronic record of the date and time of water
dumping and shock halogenation (concentration in MG/L [ppm] at
the start and completion and time) must be available for review
during inspections.
6.4.2.1.4 Retention (10)
Records must be retained on the vessel for 12 months.
6.5. Maintenance and Operating Standards for Combined Facilities
6.5.1 Pool with Attached Whirlpool Spa (10)
For any pool with an attached WHIRLPOOL SPA where the water, recirculation
system EQUIPMENT, or filters are shared with the spa, all elements of the
WHIRLPOOL SPA standards must apply to the pool.
6.5.1.2 Fecal Accidents (10)
For combined facilities subject to fecal accidents, fecal accident
procedures must include all features of these combined facilities.
6.6 Private Cabin Operations
WHIRLPOOL SPAS similar in design and construction to public
WHIRLPOOL SPAS but located for the sole use of an individual cabin or
groups of cabins must comply with the public WHIRLPOOL SPA
requirements if the WHIRLPOOL SPA
• Has a tub capacity of more than 4 individuals OR
• Can be accessed without entering the cabin.
6.6.1 Maintenance
6.6.1.1 Cleaning (10)
Private WHIRLPOOL SPAS located in individual passenger cabins must
be cleaned and disinfected, including associated recirculation systems,
between occupancies or weekly, whichever is more frequent.
6.0 Recreational Water Facilities (RWFs); 75