7.4.2.4.5 Beverage Line Cooling (20)
BEVERAGE tubing and cold-plate BEVERAGE cooling devices
must not be installed in contact with stored ice. This guidance
does not apply to cold plates constructed integrally without
SEAMS in an ice storage bin.
7.4.2.4.6 Equipment Drainage (21)
EQUIPMENT compartments subject to accumulation of moisture
because of conditions such as condensation, FOOD or
BEVERAGE drip, or water from melting ice must be sloped to an
outlet that allows complete draining.
7.4.2.4.7 Drain Lines (20)
Liquid waste drain lines must not pass through an ice machine or
ice storage bin.
7.4.2.4.8 Condenser Unit (21)
If a condenser unit is an integral component of EQUIPMENT, the
condenser unit must be separated from the FOOD and FOOD
STORAGE space by a dustproof barrier.
7.4.2.4.9 Ambient Air TMDs (21)
TEMPERATURE-MEASURING DEVICES must conform to the
following guidelines:
• In a mechanically refrigerated FOOD storage unit, the
sensor of a TEMPERATURE-MEASURING DEVICE
must be located to measure the air temperature in the
warmest part of the unit.
• In a hot-FOOD storage unit, the sensor of a
TEMPERATURE-MEASURING DEVICE must be located
to measure the air temperature in the coolest part of the
unit.
• Cold or hot holding EQUIPMENT used for
POTENTIALLY HAZARDOUS FOOD must be designed
to include and must be equipped with at least one integral
or affixed TEMPERATURE-MEASURING DEVICE that
is located to allow easy viewing of the device’s temperature
display.
• The above bullets do not apply to EQUIPMENT for which
the placement of a TEMPERATURE-MEASURING
DEVICE is not a practical means for measuring the
ambient air surrounding the FOOD because of the design,
7.0 Food Safety; 121