                              7.5.1.1.1     Water TMD Accuracy (22)
                                            Water TEMPERATURE-MEASURING DEVICES scaled
                                                •  In Celsius or dually scaled in Celsius and Fahrenheit must
                                                   be designed to be accurate to ± 1.5°C (± 3°F) in the
                                                   intended range of use.
                                                •  Only in Fahrenheit must be designed to be accurate to ±
                                                   3°F in the intended range of use.

                              7.5.1.1.2     Pressure Gauge Accuracy (22)
                                            Pressure measuring devices that display pressures in the water
                                            supply line for the fresh hot water sanitizing rinse must have
                                            increments of 7 kilopascals (1 pound per square inch or 0.07 bar)
                                            or smaller and must be accurate to ±14 kilopascals (±2 pounds per
                                            square inch or ±0.14 bar) in the 100–170 kilopascals (15–
                                            25 pounds per square inch or 1.03–1.72 bars) range.

                          7.5.1.2    Warewashing Functionality

                              7.5.1.2.1     Water TMDs Readable (22)
                                            Water TEMPERATURE-MEASURING DEVICES must be
                                            designed to be easily readable.

                              7.5.1.2.2     Water TMD Scale (22)
                                            Water TEMPERATURE-MEASURING DEVICES on
                                            WAREWASHING machines must have a numerical scale, printed
                                            record, or digital readout in increments no greater than 1°C (2°F)
                                            in the intended range of use.


                              7.5.1.2.3     Warewasher Data Plate (22)
                                            A WAREWASHING machine must be provided with an easily
                                            ACCESSIBLE and readable data plate affixed to or posted
                                            adjacent to the machine that indicates the machine’s design and
                                            operating specifications including the
                                                •  Wash tank, rinse tank(s) if present, and final sanitizing
                                                   rinse temperatures.
                                                •  Pressure required for the fresh water sanitizing rinse unless
                                                   the machine is designed to use only a pumped sanitizing
                                                   rinse.
                                                •  Conveyor speed in meters or feet per minute or minimum
                                                   transit time for belt conveyor machines, minimum transit
                                                   time for rack conveyor machines, and wash and final
                                                   sanitizing rinse times as specified by the manufacturer for
                                                   stationary rack machines.