                       29.11.3  Analyzer Probes
                                For WHIRLPOOL SPAS and SPA POOLS, analyzer probes for the dosing and
                                recording system must be capable of measuring and recording levels up to 10
                                MG/L (10 ppm).

                       29.11.4  Alarm
                                Provide an audible alarm in a continuously occupied watch station (e.g., the
                                engine control room) to indicate low and high free HALOGEN and PH readings
                                in each RECREATIONAL WATER FACILITY.

                       29.11.5  Water Feature Design
                                Design water features such that the water cannot be taken directly from the
                                compensation or make-up tank but must be first routed through filtration and
                                DISINFECTION systems.

                       29.11.6  Water Supply
                                Water may be taken directly from the RECREATIONAL WATER FACILITY
                                to supply other features within the  same RECREATIONAL WATER
                                FACILITY.

                                If taken from the RECREATIONAL WATER FACILITY, consider taking the
                                water from the lower  part of the RECREATIONAL WATER FACILITY. This
                                does not apply to a BABY-ONLY WATER FACILITY.

                   29.12  Secondary Disinfection


                       29.12.1  Installation
                                Install a secondary DISINFECTION system for each CHILDREN’S POOL,
                                INTERACTIVE RECREATIONAL WATER FACILITIES, and BABY-ONLY
                                WATER  FACILITY. Refer to section 30.3 for proper equipment and
                                installation.

                                If an ACTIVITY POOL has INTERACTIVE RWF features, such as flowing,
                                misting, sprinkling, jetting, and waterfalls, a secondary DISINFECTION system
                                must be installed.

                   29.13  Recreational Water Facility Mechanical Room (Pump Room)

                       29.13.1  Accessible
                                Make RECREATIONAL WATER FACILITY mechanical rooms
                                ACCESSIBLE and well-ventilated.

                       29.13.2  Design
                                Design pump rooms so operators are not required to stoop, bend, or crawl  and
                                so they can easily access and perform routine maintenance and duties.