Page 106 - Vessel Sanitation Program 2018 Construction Guidelines
P. 106

VSP 2018 Construction Guidelines



                                public RECREATIONAL WATER FACILITIES. Ensure commercial filtration
                                rates for calculations are used for cartridge filters if multiple rates are provided
                                by the manufacturer.


                       29.9.3   Backwash
                                Ensure media-type filters are capable of being backwashed. Provide a clear
                                sight glass on the backwash side of all media filters.

                       29.9.4   Accessories
                                Install filter accessories, such as pressure gauges, air-relief valves, and flow
                                meters. Install safety features on delivery lines to control chemical dosing
                                unless the design of the system prevents water flow to analyzers if circulation
                                fails.

                       29.9.5   Access
                                Design and install filters and filter housings in a manner that allows access for
                                inspection, cleaning, and maintenance.


                       29.9.6   Manufacturer’s Information
                                Provide manufacturer’s specifications and recommendations for filtration
                                systems.


                   29.10  Turnover Rates
                          Install recirculation pumps, filtration, and DISINFECTION equipment that have the
                          capacity to turn over water in the RECREATIONAL WATER FACILITY at the
                          appropriate rates as set forth in table the below.

                          Ensure that TURNOVER rates may be increased based on bather load. (The
                          maximum bather load must be based on the following factor: One person per 19 liters
                          [5 gallons] per minute of recirculation flow.)

                           RECREATIONAL WATER FACILITY                          TURNOVER Rate
                           SWIMMING POOL                                        4 hours
                           CHILDREN’S POOL                                      0.5 hours
                           WADING POOL                                          1 hour
                           WHIRLPOOL SPA                                        0.5 hours
                           SPA POOL                                             2 hours
                           INTERACTIVE RECREATIONAL WATER                       1 hour
                           FACILITY or ACTIVITY POOL
                           (< 610 millimeters [24 inches] deep)
                           INTERACTIVE RECREATIONAL WATER                       2 hours
                           FACILITY or ACTIVITY POOL
                           (> 610 millimeters [24 inches] deep)
                           BABY-ONLY WATER FACILITY                             0.5 hours
                           Custom installations (where the above  is not        To be determined by design
                           applicable)                                          engineer with VSP review